DESCRIPTION OF THE PRODUCT
2

ACTUATOR CHARACTERISTICS

The LINCE actuators are constructed to form part of a
sliding gate automation system.
This control panel, with built in control panel, is
equipped with a soft stop system which reduces speed
at the end of the opening and closing operations, in
order to prevent impacts and bangs to the gate.
General characteristics
• LIS424 - LIS624: Power supply 230Vac, 50Hz,
earthed
• LIS424M - LIS624M: Power supply 125Vac, 60Hz,
earthed
• Control of the travel by way of encoder
• Adjustable speed
• Adjustable maximum force
Notable characteristics
Self-testing of photocells (programmable)
The panel tests the photocells before starting each
operation. Should a failure be detected, the operation
is not carried out.
Garage light (programmable)
The garage light time can be programmed between 3
and 240 seconds. Time begins to count when operation
starts.
Flashing light
The light remains on during the opening and closing
operations.
The light goes off when the operation concludes. The
light goes off whenever operation is interrupted at a
specific point.
Operation warning function (programmable)
This function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn us that operation is about to begin.
Signal light
A signal light can be connected if the AEPS1-001 card
is installed. Using colour lights, these will indicate the
suitability or otherwise of crossing the gate.
• Off: gate closed
• Green light: gate open, free passage
• Red light: gate in movement, passage forbidden
• Intermittent green light: open gate about to close (in
automatic mode)
44
Installation Manual
This actuator allows us to fulfil the requirements of
standard EN 12453 without the use of peripheral
elements.
• Adjustable standby time in automatic cycle
• Opening and closing safety device terminals (safety
strips or photocells)
• Connector for plug-in receiver
• Connector for light signal card (AEPS1-001)
• 24Vdc terminal for peripheral connection
• Emergency battery input
SCA Light
A 24V SCA light can be connected.
• The light remains off when the gate is closed.
• The SCA light remains on statically when the gate is
open.
• During opening, the SCA light flashes every second.
• During closing, the SCA light flashes every half a
second.
Soft stop function (programmable)
Function which reduces the speed of the motor at the
end of the opening and closing operation.
24Vdc battery (bA)
It is possible to connect a battery in order for the
actuator to continue working in the event of a drop in
power. The battery will be recharged when the
electricity supply is restored.
Reset (rS)
Reset is the closed gate position search at slow speed.
The display shows rS.
The actuator carries out a reset in the following cases:
• When the electricity supply is restored following
interruption, and an operation device is activated
• When the actuator for manual operation is unlocked
and locked again
• When the gate collides with an obstacle three
consecutive times