Erreka LINCE Manuel De L'installateur page 60

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

START UP AND PROGRAMMING
Radio Code Recording (only with RSD) and Gate Travel (D1= "P")
O
Before recording the gate travel, ensure the
rotation direction of the actuator is correct (see
"Prior Conditions Programming (D1= "C")" on
page 55).
The recording of the radio code described below is
only valid if the plug-in receiver RSD is installed. If
another receiver is used, record the radio code as
described in the corresponding instructions.
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
P flashing. Press ENTER to confirm. D2 flashes.
D1
D2
D3
P
1
o
2
o
3
o
Main Functions Programming (D1= "F")
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
F flashing. Press ENTER to confirm. D2 flashes.
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
D1
D2
Parameter
F
1
Operation mode
2
Standby in automatic mode
3
Pedestrian opening
a. For further details, see "Operation modes" on page 46.
56
Installation Manual
until D1 shows the letter
V
D4
ç
Total opening radio code
recording
ç
Pedestrian opening radio
code recording
ç
Gate travel recording
until D1 shows the letter
V
until the required D2
V
D3
0
a
0
1
0...5. 0...9
0
1
2
3
4
5
3 Press the buttons ^ and
parameter appears (see chart). Press ENTER to
confirm. D3 and D4 flash.
4.a Radio code recording (D2=1 or D2=2):
• Press the emitter button. If the code is correctly
recorded, D3-D4 stop flashing (remain static).
4.b Gate travel recording (D2=3):
• Press ENTER. D3-D4 stop flashing (remain static)
• Press the total opening button. D3-D4 flash
again whilst the recording of the operations is
made automatically. The gate carries out the
following movements:
– Reset (close position search)
– Total opening
– Total close
• When recording is finished, D3-D4 stop flashing
(remaining static).
5 Press ESC to return to the previous display.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
For operation different to the options defined in this
menu, access the advanced functions menu (see
"Advanced Functions Programming (D1= "A")" on
page 57).
P r e -
D4
d e t e r m i n e d
Options or values
option
1
Automatic
2
x
Semi-automatic
5
x
15 seconds
59
0
x
Pedestrian opening is not carried out
0
10% of total opening
0
20% of total opening
0
30% of total opening
0
40% of total opening
0
50% of total opening
until the required D2
V
until the required D3 and
V
2.5
= 59 sec;
= 2 min. 50 sec, etc

Publicité

Table des Matières
loading