Advanced Functions Programming (D1= "A")
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
A flashing. Press ENTER to confirm. D2 flashes.
D1
D2
Parameter
A
0
Flashing light
1
Garage light time
2
Gate speed
3
Soft stop speed
4
Soft stop function
5
Recede after closing (allows
offsetting of gate expansion)
6
Maximum force
7
Closing photocell used during
standby (in automatic mode
only)
8
Pushbutton operation during
standby (in automatic mode
only)
9
Opening mode
until D1 shows the letter
V
D3
D4
0
1
0
2
0
3
0...5. 0...9
0
1...5
0
1...5
0
0...5
0
0...9
0
8
0...1
0...9
0
1
0
2
0
3
0
1
0
2
0
3
0
1
0
2
0
3
START UP AND PROGRAMMING
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
P r e -
determined
Options or values
option
x
No warning
With warning
x
3 sec.
59
= 59 sec;
05
01
: minimum speed;
03
01
: minimum speed;
01
00
: minimum distance;
05
: maximum distance
01
00
: no recede;
x
01
: minimum force;
Immediate close
x
Restart standby time
Has no effect
Immediate close
x
Restart standby time
Has no effect
x
Opening in accordance with the mode
selected in the main functions (F)
Community opening
( t h e con trol p an e l do es not o be y t he
commands during opening)
Step-by-step opening
(the gate halts if an operation device is
activated during opening. The gate closes
when operated again)
until the required D2
V
until the required D3 and
V
2.5
= 2 min. 50 sec, etc
05
: maximum speed
05
: maximum speed
09
: maximum recede
10
: maximum force
LINCE actuator for sliding gates