Maintenance And Diagnosis Of Failures; Maintenance; Operations Counter - Erreka LINCE Manuel De L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Before carrying out any maintenance operation, disconnect the device from the power supply.
1 Frequently check the installation in order to discover
any imbalance or sign of deterioration or wear. Do
not use the actuator if any repair or adjustment is
necessary.
2 Clean and lubricate the articulations and tracks of
the gate, so as not to increase the effort of the
actuator.
2

OPERATIONS COUNTER

1 Press ENTER to access the main programming menu.
The display lights up and D1 flashes.
2 Press the buttons ^ and
ç.
D3 and D4 show the number of operations
carried out (hundreds of operations).
D1
D2
Parameter
ç
1
Operations carried out
until D1 shows the letter
V
D3
D4
X
X
3 Check that the operation devices, safety strips and
photocells, as well as their installation, have not
suffered any damage from the weather or external
agents.
4 Check unlocking can be carried out easily.
5 Check the operations made in the display (see
"Operations Counter" below).
3 Press ESC to return.
P r e -
d e t e r m i n e d
Options or values
option
Indicates the hu ndred s of cycles
completed (for example,
6,800 cycles completed
English
68
indicates
)
LINCE actuator for sliding gates
59