BEFORE OPERATION

All the generators, when functioning normally, use the
principal of electrical separation; in these cases the Generator
should under no circumstances be earthed using the terminal
" PE" or with any other part of the generator.
In the event of the user installing differential circuit breakers,
it is important for its correct functioning that the neutral point that
corresponds to the joint of the two main coils is also earthed.
Besides the generator is preset for grounding the masses; a special
screw, marked with the symbol PE, allows all the metal parts of
the generator set to be connected to a ground plate.
GROUND TERMINAL LOCATION:
Ground
Terminal
Do not use a pipe carrying combustible material as
the ground source.

LUBRICATION

DO NOT attempt to start this engine without filling the
crank case with the proper amount and type of oil. Your
generator has been shipped from the factory without oil in the
crankcase. Operating the unit without oil can damage the
engine.
Fill the engine with oil according to the operator manual.
For units with a dipstick, fill oil to the proper level. Units
without a dipstick should be filled to the top of the opening of
the oil fill.
English
English

LOW OIL SENSOR

The unit is equipped with a low oil sensor. If the oil level
becomes lower than required, the sensor will activate a
warning device or stop the engine.
If generator shuts off and the oil level is within
specifications, check to see if generator is sitting at an angle
that forces oil to shift. Place on an even surface to correct this.
If engine fails to start, the oil level may not be sufficient to
deactivate low oil level switch. Make sure the sump is
completely full of oil.

LP GAS TANK

Do not use or store LP Gas tank in a
building, garage or enclosed area.
Do not check for leaks with a match or
flame.
The LP Gas tank valve should be OFF
(closed) when the generator is not in use.
Regulator inlet pressure range: 30 to 100 psi from LP
Gas tank.
LP Gas tank: Maximum diameter allowable of the tank
300mm. Do not use tanks that are rusted or damaged.
Verify that the re-qualification dated on the tank is not
expired.
Purging LP Gas tanks: The purging process should be
done by your LP Gas supplier. New tanks must be purged
of air and moisture before filling. Used cylinders must
also be purged if they have not been plugged or kept
closed.
Remove the safety plug or cap from the tank fuel valve.
Never allow children to tamper or play with the fuel tank
or generator.
Contact with the liquid contents of the LP Gas tank
will cause freeze burns to the skin.
15
13