Installation Conditions Of The Cylinder Valve Unit; Required Accessories - Aventics CVI Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 85
62
AVENTICS | CVI/TUS | R412004532–BDL–001–AE
Assembly
Damage to the cylinder by changing the medium!
Once oiled compressed air has been used in the system, the choice of this medium cannot be
reversed without damaging the cylinder.
Never change from oiled to oil-free compressed air.
Mounting orientation

7.2.3 Installation conditions of the cylinder valve unit

NOTICE
The valve is operated using compressed air as its pressure
medium.
The preferred medium is oil-free compressed air.
– The permissible particle size for the compressed air is
50 μm.
– The oil content of the compressed air must remain constant
over the entire service life: 0 mg/m
Only use oils approved by AVENTICS for oiled compressed air
(see the heading "Technical Information" in the online product
catalog).
Verify that the pressure dew point is at least 15°C below the
ambient and medium temperatures and does not exceed 3°C.
The cylinder valve unit can be installed in any position.
7.3

Required accessories

Depending on the chosen configuration and the system, additional
components are required to integrate the cylinder valve unit into
the system and the system control.
Accessory parts for use in explosive areas must comply with the
requirements stipulated in the European directives and national
laws.
See Table 1 on page 45.
3
3
– 5 mg/m
.

Publicité