Delivery Contents
Danger of explosion due to circulating currents!
Stray magnetic fields may cause circulating currents, e.g. near electrical drives with
asymmetrical loads, during arc welding, if the ground is conducted via the system and not
via a 0 V line, or if there is cathodic corrosion protection.
Make sure that there is protection against the possible effects of circulating currents.
Usage zones
Without coils and
sensors
4
Delivery Contents
1 fully assembled cylinder valve unit, depending on the
configuration
1 set of operating instructions
The cylinder valve unit has been individually configured
according to your requirements. You can display the exact
configuration in the AVENTICS Internet configurator under
your order number.
Ensure the full scope of delivery by comparing the delivered
cylinder valve unit with your configuration.
5
About This Product
5.1
Use in explosive areas
DANGER
The cylinder valve unit has been designed for use in explosive
areas over several consecutive days. All exterior materials consist
of suitable low-spark materials.
You can use the cylinder valve unit without coils and sensors as
follows:
within zone 1 (category 2 G) – gas explosion protection
within zone 21 (category 2 D) – dust explosion protection