Special Cases; Calibration Programmes - Corghi ProLine 650 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 81
When the spin is over the optimisation
programme has been completed and the
weights to be applied to balance the wheel
are displayed.
If an error that may affect the end result
occurs, the machine indicates it by tem-
porarily displaying the "E 6" message. The
procedure can now be repeated.

Special Cases

- The "OUT 2" message can be displayed
at the end of the first spin. In this case
it is advisable to exit the programme by
pressing the key:
the weights necessary for balancing the
wheel are displayed. The execution of
the programme is interrupted, thus not
achieving the moderate improvement of
the end results. by pressing the
key the optimisation procedure can be
continued.
- At the end of the first spin the instruction
that the tyre is to be mounted on the rim
in the reverse direction may appear. If
you do not intend to reverse the tyre or if
doing so is impossible, press the
key and the machine will provide the in-
structions for completing the programme
without reversing the tyre.
CALIbRATION
PROGRAMMES
Sensitivity Calibration
Calibrate when detecting that the setting
condition is out-of-tolerance or when the
machine so requires as the "E1" message
is displayed.
- Fit a wheel of average dimensions (pref-
erably with only small unbalance) on the
70
- Set the wheel geometric data correctly.
- Press the
- Press the key
the values of
- After the selection, the machine will
- Perform a first spin.
- At the end of the spin, turn the wheel
- Apply a sample weight of 100 grammes
- Perform a second spin.
- At the end of the spin, remove the sample
- Apply the sample weight of 100 grams
- Perform a third spin.
At the end of the spin(the message "End
CAL" will appear on the display), if the
calibration has been successful, an acoustic
consent signal goes off at the end of the
spin otherwise the message E 2 is tempo-
rarily displayed.
wheel balancer.
luminous dot corresponding to the CAL
programme
selection.
display the message:
• CAL on the left-hand display;
• GO on the right-hand display.
until it reaches the position marked by
the position indicator and the message
"100" ("3.5" if the ounces view mode has
been selected) is displayed.
(3.5 oz) on the INNER side of the rim, at
exactly 12 o'clock.
weight and turn the wheel until it reaches
the position marked by the position in-
dicator and the message "100" (or "3.5")
is displayed.
(3.5 oz) to the OUTSIDE of the rim, at
exactly 12 o'clock.
This last calibration phase includes the
execution of three consecutive spins in
automatic mode.
User manual ProLine 650
keys until the
illuminates.
to confirm the

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières