The machine can recognise a certain number of malfunction conditions and signals them
to the user by visualising the relevant messages on the displays.
A 3
wheel not suitable for performing the sensitivity calibration, use a wheel of
average dimensions (typically 5.5"X1440") or larger but with a weight that
does not exceed 40 kg.
A 5
Incorrect dimension settings for an ALU programme. Correct the set dimensions.
A 7
The machine is temporarily not enabled to select the programme requested.
Perform a wheel spin, then repeat the request.
A 10
Internal sensor not in the rest position. Return the sensor to the rest position
(completely in). If the message does not disappear, internal sensor operation
can be disabled by pressing the
A 20
Sensor in incorrect position during calibration.
Bring it to the position indicated and repeat the calibration.
A 23
Incomplete or incorrect data entry in ALU P.
Repeat the input correctly.
A 26
Programme available only after selecting one of the following programmes:
ALU 1P / ALU 2P / Motorcycle Dynamic / Alu Motorcycle or if selected in the
Motorcycle programme but with the wheel NOT in the centred position.
A 41
Incorrect wheel spin procedure on the wheel balancer without guard. The warn-
ing appears when the spin button is pressed for more than 10 seconds without
pressing the "START" key at the same time. Release the button and spin the
wheel according to the procedure indicated in the "Wheel Spin" paragraph.
If the problem persists, call in the technical support centre.
A Stp
Wheel stop during the spin phase.
Wheel movement is not integral with swinging unit movement: Check correct
wheel tightening.
A Cr
Spin performed with the guard raised.
Lower the guard to perform the wheel spin.
In machine versions with the spin push button, release either the START but-
ton or the push button during the spin.
Carry out the spin holding down both the START button and the push button.
E 1
Absence of sensitivity calibration.
Perform the sensitivity calibration procedure.
E 2
Error condition on sensitivity calibration.
Repeat the sensitivity calibration, paying attention to the first spin, which
must be performed with the wheel like the subsequent spins.
Take particular care NOT to knock the machine during calibration.
96

DISPLAY MESSAGES

– A – Notice Messages
– E – Error messages
button.
EM 7240 Operator's manual