Checking Ip69K Protection And Seals - Aventics CL03 Notice D'instruction

Masquer les pouces Voir aussi pour CL03:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 105
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF
8.4.3 Changing the pilot air supply
Fig. 16: Pilot air supply
1. Undo the two hexagon screws (25) with a 7 mm wrench and
remove the pilot air cover (26).
2. Place the seal (27) in the desired position by turning
it so that the indicator dot (28) is in the correct position.
3. Replace the pilot air cover (26) and tighten the two hexagon
screws (25).
Tightening torque: 1.0-1.2 Nm
8.5

Checking IP69K protection and seals

Risk of damage to the valve system!
Too high pressure when connecting compressed air
to the exhaust air connection may damage the unit.
Do not exceed 0.7 bar (for CL03) or 0.3 bar (for CL03-XL)
when connecting compressed air to the "Vent"
connection.
Conversion and Extension
25
26
27
CAUTION
95
28

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cl03-xl

Table des Matières