AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF
22
Fig. 12: Installing the subbase
1. Screw the three tie rod extensions (21), supplied in the tie
rod extension kit, approximately 10 mm into the tie rod
nuts (22).
2. Check whether the seal (23) is seated correctly on the valve
system subbase.
3. Slide the subbase (3) onto the tie rods. Pay attention that
the seal is positioned correctly.
4. Place the three tie rod nuts (22) onto the tie rods in the new
subbase and tighten them.
Tightening torque: 2.0–2.5 Nm
5. Align the tie rods nuts so that one of the six wrench flats
is parallel to the top of the subbase.
The tie rod nuts now fit in the recesses of the next plate.
To mount further subbases:
6. Repeat steps 1–5.
Conversion and Extension
5
21
3
23
89
22