Fig. 3:
Dimensional drawing, valve systems CL03 and CL03-XL, metric versions
L = 87.5 mm + (M x 30 mm) + (N x 36 mm)
1)
G
= 25.25 mm + (M x 30 mm) + (N x 36 mm)
2)
G
= 12.25 mm + (M x 30 mm) + (N x 36 mm)
F = 57.25 mm + (M x 30 mm) + (N x 36 mm)
M = number M x CL03 base plate; N = number M x CL03-XL base plate
1)
Mounting to subbase with 4 push-in fittings
2)
Mounting to subbase with 4 push-in fittings
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF
180,8
1
1
1
1
149
169
2
L = 127.25 mm + (M x 30 mm) + (N x 36 mm)
G = 30.4 mm + (N - 1)x 30 mm* + 15 mm
F = 57.25 mm + (M x 30 mm) + (N x 36 mm)
89,15
78,5
1
1
1
42 42
1
92,8
11,5
76,15
67
Assembly