6.1.1
See Fig. 8
1. Remove the dummy plate (2) with 2 Philips screws (4),
2. Place the valve (3) on the free subplate. Make sure the
3. Screw the valve (3) tight using 2 self-cutting Philips
4. Move the manual overrides into zero position.
See section 4.2
See section 4.3
6.1.2
See Fig. 8
1. Remove the dummy plate (2) with 2 Philips screws (4),
2. Place the supply plate (1) on the free subplate. Ensure that
3. Screw the supply plate (1) tight using 2 self-cutting
See section 4.2
AVENTICS | MC | 1987765452–BDL–001–AE
Inserting a valve
type Z, size 1 ("Pozidrive").
gasket is seated correctly and that the contacts are straight.
screws (5), type Z, size 1 ("Pozidrive").
Tightening torque: 1.1 ... 1.3 Nm.
Power wrench speed: 300 ... 600 rpm.
5. Set up pneumatic connections.
6. Make electrical connections if the multiple plug connector
pins that are assigned to this position have not yet been
connected.
Inserting the supply plate
type Z, size 1 ("Pozidrive").
the gasket has been inserted correctly.
Philips screws (5), type Z, size 1 ("Pozidrive").
Tightening torque: 1.1 ... 1.3 Nm.
Power wrench speed: 300 ... 600 rpm.
4. Set up pneumatic connections.
Conversion and extension
53