Type 1062
Assembly
Fully tighten the duplication rod on
the actuator rod using a screwdriver
with a blade of suitable size.
Depressurize the actuator of a valve
which is normally closed (function
"A") or has a double effect (function
"I"): the valve recovers its default
position.
Insert the position feedback housing
into the duplication system "D"
setting the cable gland in the
direction desired and making sure,
on a mechanical contact version,
that you do not damage the contact
levers on the switches.
C
Fasten the housing and the dupli-
D
cation system by tightening the cone
point set screw "C" using a hex-
agonal male spanner.
K
L
7.4
fitting the position feedback with
stroke limiter to a pneumatic
actuator size 50 to 80mm
note
the tightness of the actuator is not guaranteed when the
transparent cap is removed.
▶ Prevent the projection of fluids into the actuator.
the tightness of the position feedback is not guaranteed
when the cover is removed.
▶ Prevent the projection of fluids into the position feedback.
english
Unscrew the cover "K" on the
position feedback.
Unscrew the cable gland "L".
Thread the cable through the cable
gland.
Wire according to the wiring
diagram for your version of the 1062:
See chap. „8 Installation and wiring".
Fasten the cable gland to ensure
tightness of the product.