Characteristic
Turbo Pump
TMP Flange
Forepump
Voltage
Base Pressure *
N
Pumping Speed (L/s)
2
He Pumping Speed (L/s)
H
Pumping Speed (L/s)
2
TMP Rotational Speed
Start-up time
Operating Position
Ambient Temperature
Bakeout Temperature
Protection Breaker
Installation category
Pollution Degree
Compliance with:
Indoor Use Only
Max altitude 2000m
Serial Communication kit
Storage Temperature
* According to standard DIN 28 428, the base pressure is that measured in a leak-free test dome, 48
hours after the completion of test dome bake-out, with a Turbopump fitted with a ConFlat flange.
TPS-mobile User Manual / 87-901-005-01 (F)
9698433
9698432
TV551
TV551
CFF8
CFF8
TS600
TS300
110 V / 60 Hz
1x10
mbar (7.5x10
-9
On a flat floor
+5 °C to +35 °C
max 120 °C on Inlet Flange
EN 55011 (Class A Group 1)
EN 61326-1
EN 61010-1
EN 1012-2
EN 12100
-20 °C to +70 °C
Technical Information
Technical Specification
9698431
TV551
CFF8
DS402
Torr)
-10
550
600
510
40000 rpm
<5 min.
25 A
II
2
None
17
9698430
TV551
CFF8
DS302
351/400