Fig 7 Connection bar for progressive distributors

2.3 Pump unit installation

The pump unit should be installed in a way which ensures protection against dirt, splash
water and vibration but also provides for easy access to make sure that all further
installation works can be carried out without difficulty and the unit can be easily refilled
later. The liquid level of the reservoir should be clearly visible. The unit must be installed in
vertical position.
For installation, the unit is equipped with a connection flange with three fixing points.
Mount the SKF Multipoint automatic lubricators LAGD 1000 to the machine with the three
supplied M8 bolts, washers and self-locking nuts (Tightening torque: 16 Nm, 11.8 ft.lbs).
The unit should be mounted in a position that is protected to the greatest possible extent.
Where holes have to be drilled for installation, position these holes as shown below, using
the template in Appendix 1.
When drilling the mounting holes, be aware of possible sources of danger,
such as available supply pipes, other units, non-stationary parts and heat
sources. Ask the machine manufacturer to confirm the position of the
mounting holes
Fitting with less than three screws is not allowed and may result in
breakage of the assembly flange.
The installation surface must be even. Otherwise the assembly flange may
be overloaded when tightening the screws and break.
Mount the unit at a safe distance from other items and conform to local
installation and accident prevention regulations.