Fig 14 Shorten the plastic pipe
Use a grease gun to pre-fill the cut pipes. Firmly push the pipe into the open end of the
pipe filling nipple included with the lubricator. Connect the grease gun to the other end of
the filling nipple. Operate the grease gun to fill the pipe with grease. To remove the grease
filled pipe, push on the collar and at the same time pull out the pipe.
If the end of the pipe is damaged by the filling nipple, cut off the damaged end before you
connect the lubrication pipe to the divider block.
Push the pipes into the outlet of divider block. Lightly pull on each lubrication pipe to
ensure that a firm connection is made. The lubrication pipes can be routed.
Fix the lubrication pipes to suitable positions on the machine by means of the enclosed
cable ties. Cut the protruding ends of the cable tapes with scissors or a similar tool.
When routing the lubrication pipes, make sure that the pipes cannot be
bent, squeezed, sheared off nor rubbed through during operation.
Insert the pipes into the connectors fitted to the application. Lightly pull on each
lubrication pipe to ensure that a firm connection made.
Fig 15 Insert the plastic pipe into the fitting.
To detach the pipe, press the plastic pipe forcefully into the fitting and pull it out.