Parameterisation; Reading The Digital Display - HYDAC ELECTRONIC ENS 3000 Notice D'utilisation

Masquer les pouces Voir aussi pour ENS 3000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENS 3000 IO-Link
8

Parameterisation

The level switch can be parameterised via the device keys or via the IO-Link interface by
means of any IO-Link compatible master configuration tool (according IO-specifications
V1.1). Supports IO-Link specifications V1.0
Should the read parameter sets from the device not be accepted, we recommend to carry
out a plausibility check of the parameter set.
For detailed information on IO-Link device parameters, factory defaults, process and
diagnostic data, supported standard system commands as well as additional HYDAC
device specific system commands for the various product versions (part numbers), please
refer to the corresponding IODD (IO Device Description).
You will find the link for download on our homepage at
→Products→Sensors→Product search
(http://www.hydac.com/uk-en/products/sensors/show/Material/index.html)
Entering the part number (9xxxxx) the corresponding ZIP file appears
9

Reading the digital display

Designation
Switch point, output 1
Switch-back point, output 1
Switch point, output 2
Switch-back point, output 2
Fluid level window top value,
output 1
Fluid level window bottom value,
output 1
Fluid level window top value,
output 2
Fluid level window bottom value,
output 2
Extended functions
Reset to factory defaults
Assignment shown value display
Level
Temperature
Assignment shown value
output 1
Assignment shown value
output 2
Switching delay time, output 1
Switching delay time, output 2
Version 2014/12/11
Representation on
7-segment display
sp1
rp1
sp2
rp2
fk1
fl1
fk2
FL2
ef
res
Seld
MiU
MEnP
Src1
Src2
ds1
ds2
HYDAC ELECTRONIC GMBH
page 12
ASCII
representation
SP1
RP1
SP2
RP2
FH1
FL1
FH2
FL2
EF
RES
SELd
NiV
TEmP
Src1
Src2
dS1
dS2
Part No. 669898

Publicité

Table des Matières
loading

Table des Matières