Safety information

Before commissioning, check the instrument and any accessories supplied. Before
commissioning, please read the operating instructions. Ensure that the instrument is
suitable for your application.
If the instrument is not handled correctly, or if the operating instructions and specifications
are not adhered to, damage to property or personal injury can result.

Exclusion of liability

2
This operating manual was made to the best of our knowledge. Nevertheless and despite
the greatest care, it cannot be excluded that mistakes could have crept in. Therefore
please understand that in the absence of any provisions to the contrary hereinafter our
warranty and liability – for any legal reasons whatsoever – are excluded in respect of the
information in this operating manual. In particular, we shall not be liable for lost profit or
other financial loss. This exclusion of liability does not apply in cases of intent and gross
negligence. Moreover, it does not apply to defects which have been deceitfully concealed
or whose absence has been guaranteed, nor in cases of culpable harm to life, physical
injury and damage to health. If we negligently breach any material contractual obligation,
our liability shall be limited to foreseeable damage. Claims due to the Product Liability shall
remain unaffected.
In the event of translation, only the original version of the operating manual in German is
legally valid.
3

Functions of the ENS 3000

Depending on the model, the instrument has the following functions:
• Supports IO-Link specifications V1.1 and V1.0
• Supports SIO mode
• Display of the switching states in SIO mode
• Mode display (SIO or SDCI)
• Adaptation to the corresponding application using specific parameter settings
• Display of the actual fluid level in cm or inch (depending on version)
• Display of the actual temperature in °C or °F (depending on version)
• Display of the minimum and maximum value of fluid level or temperature or of a pre-
set switching point
• Switching of the switch outputs based on the fluid level or temperature and the pre-
set switch parameters
• Analogue output
• Program enable
Version 2014/12/11