Pipework installation

To be done by an authorized plumber.
Fig. 6 Home type steam generator
A= Connection
B= Lock nut
C= Steam outlet
D= Drainage connection (safety valve)
E= Water connection with built-in dirt fi lter
F= Drainage connection (motorized valve)
Fig. 7 Commercial type steam generator
A= Connection
B= Lock nut
C= Steam outlet
D= Drainage connection (safety valve)
E= Water connection with built-in dirt fi lter
F= Drainage connection (motorized valve)

Water connection

Connect cold water to connection 1 (Fig. 6,7) on the steam gene-
rator. The incoming water pressure must be between min. 0.2 and
max 10 bar (min. 20kPa and max 1000kPa).
To avoid banging, the water connection between the copper pi-
ping (internal dia. min. 12 mm) and the steam generator to consist
of approx. 1 meter of fl exible armored rubber hose.
Important! Before the incoming water connection is made to the
steam generator, the piping system must be fl ushed clean!
Flushing clean prevents metal particles and other foreign objects
entering the steam generator system from the piping.
Also remember to install the accompanying non-return valve into
the incoming water connection
NB:
In areas with hard water, exceeding 4°dH hardness, a water
softener or a "Tylö de-calcifi er" must be installed (Tylö Item No.:
9090 8025). The water softener must not produce foam or give off
harmful chemicals.

Steam pipe

Fit the connector, with the lock nut uppermost, to steam outlet 2
(Fig. 6,7) on the steam generator. Connect a copper pipe, with
an internal diameter of at least 18mm, to the connector steam
outlet (C). The steam pipe can have a down-slope either towards
the steam room or towards the steam generator. Alternatively the
steam pipe can be installed with a slope down towards both the
steam room and towards the steam generator.
IMPORTANT!
Water pockets in the steam pipe between the steam generator
and the steam room, where condensed water can collect, must
not be present.
Fig. 8
21