Modular Connector Description - Tylo Steam Home 9 Installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
26
During operation the steam generator is emptied automatically after 4 hours (factory setting, via settings > auto emptying can be alte-
red) in order to ensure good water quality. When 2 or 3 generators are connected together, the "Secondary"-generators are emptied at
20 minute intervals after the "Primary" has been emptied.
The connections between the generators use a low power cable (2 core, RJ10 2P4C A/B) with an RJ10 connector, (Fig. 16.)
Refer to the section "Modular connector description" (Fig.17) for more information on the pin confi guration.
1
Fig. 16
* = option
If one steam generator needs servicing the others can remain in operation. One generator that is set as a secondary is disconnected
by removing the cable from between the circuit boards. (Fig. 16)
If the generator that is to be serviced is set as the "primary", do as follows:
1.
Use the circuit breaker to switch off the generator.
2.
Disconnect the cable that connects the control circuit boards (Fig. 16)
3.
Select a "secondary" steam generator and change the DIP switch settings to "primary" according to the appropriate type. Refer to
Fig. 15. Then connect the control panel to the new "primary". A new "initial setup" will be requested, as the generator had not been
set up as a "primary" earlier.

Modular connector description

Pos 1.
Pos 2.
Pos 3.
NTC
Ext sw
Door sw
Pin 1:
Pin 1:
Pin 1:
Pin 2: NTC
Pin 2: LED
Pin 2: LED
Pin 3: NTC
Pin 3: SW
Pin 3: SW
Pin 4:
Pin 4: 12 V
Pin 4: 12 V
1
2
3
Pos 6-9.
6
7
4x RS485
Pin 1: A
Pin 2: B
Pin 3: 12 V
Pin 4: GND
Fig. 17
1.
NTC Sensor (RJ10)
2.
External switch (RJ10)
3.
Door contact (RJ10)
4.
SEC/NTC Sensor (option) (RJ10)
Connecting components to the modular contacts (maximum cable cross-sectional area for RJ10. 0.9mm/ 0.2mm², AWG24)
Unit
Temp.sensor (10kΩ)
External switch without LED indication
External switch with LED indication
Door contact without alarm for door status
Door contact with alarm for door status
Synchronisation cable A/B
2*
Pos 4.
Pos 5.
Bim/NTC
Addon (option)
Pin 1: Bim
Pin 2: NTC
Pin 3: NTC
Pin 4: Bim
4
5
8
9
5.
Addon (option for Home)(RJ45)
6-9. RS485 control panels (RJ10)/
Synchronisation cable A/B
Pos
Pin
Comment
1
2-3
Must be NTC type. May also be connected at Position 4.
2
3-4
Both constant and impulse deactivation work.
2
2-3-4
12VDC (maximum 40mA). Tylö external switch, item number: 9090 8045
3
3-4
Of type NO (Normally Open). Tylö door contact, Item No.: 9090 8035.
3
2-3-4
12VDC (max. 40mA)
6-9
1-2
Multisteam
3*
Sync cable A/B
1 2 3 4
10
Pin:
1
2
3
4
10. Modular plug (RJ10)
11. Modular contact (RJ10)
1 2 3 4
A
B
Pin:
4
3
2
1
11

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières