Rohs (Restriction Of Hazardous Substances) - Tylo Steam Home 9 Installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
Error
Symptom
code
Steam tank level
12
electrodes are not
working, mid failure.
Contact lost with the
15
heater network relay
board node.
Too many secondary
18
units connected.
Door has been open
for longer than the
19
permitted time. Current
session ends
Door switch has been
open for longer than
20
60 seconds since the
previous session.

ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES)

Instructions for environmental protection.
Do not dispose of this product with the domestic refuse when no
longer in use. Take it to a recycling station for electrical and
electronic equipment.
For further information, see the symbol on the product, manual or
packaging.
Fig 20: Symbol
The diff erent materials can be recycled as specifi ed by their label-
ling. You can help protect the environment by recycling or reusing
the spent appliances or the materials in them. Take the product
to a recycling centre without the sauna stones or the soapstone
jacket (if fi tted).
Contact your local authorities for details of your nearest recycling
centre.
Error
Events during error
occurs
Operation is interrupted and error
During
code clearing takes place immedi-
operation
ately.
Error code clearing takes place
At off
immediately.
Operation is interrupted and reboo-
ting takes place. For steam produc-
During
tion, emptying takes place immedi-
operation
ately after rebooting is completed in
case there is water in the tank.
Reboot. For steam production,
emptying takes place immediately
At off
after rebooting is completed in case
there is water in the tank.
Error code appears immediately after
During
voltage is applied to the system,
operation
resulting in the system constantly
rebooting.
Error code appears immediately after
voltage is applied to the system,
At off
resulting in the system constantly
rebooting.
Operation interrupted. Emptying of
the steam production source takes
During
place 1 hour after the error occurred.
operation
Error code triggered at standby/
operation on of the sauna/Tylarium at
steam only at operation on.
Cannot be triggered when the system
At off
is off .
Error code is only triggered at off .
Arrange it so that the steam room
cannot be started via calendar
During
entries and external control. Error
operation
code fi rst triggered hidden with the
system off , and fi rst shown at the
start attempt, and at later starts at the
Pure control panel.
Error code is only triggered at off .
Arrange it so that the steam room
At off
cannot be started via calendar entri-
es and external control.
Comments on error code
Requires a continuous failure of the mid electrode pin for 5
seconds at the same time as the high electrode pin having a
value equivalent to water, before error code will be triggered.
Check the connections between the relay board and the mid
electrode. Check if the mid electrode pins are coated with
grease. The level high electrode pins may perhaps be in
contact with GND although not a complete short-circuit but
just enough so that the value is misinterpreted as water?
Shown when the primary has lost contact with the connec-
ted secondary unit, system cures itself. Check, does the
secondary unit have voltage? Test by removing and refi tting
the RJ10 synchronization cable again. Check that one of
the pins in the female RJ10 connector on the circuit board
may have become misaligned or displaced, so that there is
no contact with the connected synchronization cable. After
rectifying the fault, restart the power to both the primary and
secondary.
Maximum number of units in the system: 1 primary + 2
secondary for Multisteam. 1 primary + 1 secondary for
Tylarium. The error code is fi rst seen on the display after
rectifi cation and system restarting.
Weekly calendar entries rescheduled to the following week.
Date calendar entries deleted. If it is known that the door
was closed all the time, test by disconnecting and reconnec-
ting the RJ10 connector. Check, is the distance between the
switch and the magnet set correctly? Check that one of the
pins in the female RJ10 connector on the circuit board may
have become misaligned or displaced, so that contact with
the connected RJ10 cable has been lost. Pins 3-4 must be
NC (Normally Closed) when the door is closed.
Check that the door switch is working by: 1. Restart the
system with the door open, then inspect the confi guration
menu status, the door switch will not now be shown as
connected. 2. Close the door and now the door switch will be
shown as closed. If its shown as not closed, is the switch or
cable faulty are incorrectly installed? Check by removing and
refi tting the RJ10 connector. Check, is the distance between
the switch and the magnet set correctly? Check that one of
the pins in the female RJ10 connector on the circuit board
may have become misaligned or displaced, so that contact
with the connected RJ10 cable has been lost. Pins 3-4 must
be NC (Normally Closed) when the door is closed.
31

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières