Error codes
Tampering with the device may only be performed by qualifi ed personnel
Error
Symptom
code
Temperature sensor
1
in the room not con-
nected or faulty
Temperature sensor
2
in the room not con-
nected or faulty
The level electrodes
4
in the steam tank are
short-circuited
The steam tank over-
5
full level electrodes
are not working.
Contact lost with the
6
heater network con-
trol panel node.
The steam tank has
8
overheated
Contact with the add-
10
on board has been
lost.
There is a fault in
the emptying of
water from the steam
11
tank. Switch off the
power and perform
servicing.
Error
Events during error
occurs
Operation interrupted. Emptying of
During
the steam production source takes
operation
place 1 hour after the error occurred.
Only the error code is shown. Steam
At off
production source does not empty.
The standby steam room with its
steam production & Tylarium stop
working and emptying takes place
During
1 hour after the error occurred. The
operation
steam room only notifi es that there is
an error. Operation is not interrupted
and emptying takes place as normal
1 hour after the steam bath ends.
Only the error code is shown. Empty-
At off
ing does not take place.
Operation is interrupted and error
During
code clearing takes place immedi-
operation
ately.
Error code clearing takes place
At off
immediately.
Operation is interrupted and error
During
code clearing takes place immedi-
operation
ately.
The error code cannot be triggered
At off
when off , operation must be started
for the incoming water feed to open.
Operation is interrupted and restar-
ting takes place. For steam produc-
During
tion, emptying takes place immedi-
operation
ately after restarting is completed in
case there is water in the tank.
Reboot. For steam production,
emptying takes place immediately
At off
after rebooting is completed in case
there is water in the tank.
Operation is interrupted and error
During
code clearing takes place immedi-
operation
ately.
Cannot be triggered when the system
At off
is off .
Operation interrupted. In a Tylarium
During
emptying of the steam secondary
operation
is taking place 1 hour after the fault
occurred.
Only the error code is shown. In
At off
a Tylarium emptying of the steam
secondary is not taking place.
Fault detected during the actual
emptying sequence of the system.
During
Error code clearing, Automatic
operation
emptying, Voltage connection to the
system and water in the tank and
emptying after session completed.
Fault detected during the actual
emptying sequence of the system.
Error code clearing, Automatic
At off
emptying, Voltage connection to the
system and water in the tank and
emptying after session completed.
Comments on error code
Is the sensor intact? Is it giving an incorrect value? Resistan-
ce measurement should show approx. 10kΩ at 25˚C and
approx. 677 Ω at 100˚C.
Is the sensor intact? Is it giving an incorrect value? Resistan-
ce measurement should show approx. 10kΩ at 25˚C and
approx. 677 Ω at 100˚C. This sensor must be changed if it is
faulty, otherwise the standby function of the system cannot
be used.
About 5 seconds of continuous failure is required to trigger
an error code. Check that the electrode pins are touching the
electrode tube or alternatively the cables. Error code may
be triggered by water with a high concentration of salt or
minerals that increases electrical conduction and makes the
circuit board believe that the electrodes are short-circuited.
In that case clean/descale the water tank and the electrode
pins.
The uppermost, high (H) electrode has not detected the
water level within the preset time, refer to the fi lling time
in the confi guration menu. Insuffi cient water fl ow? Is the
incoming water switched on? Is there a gap in the electrode
wire connections GND/high? Grease on the coating surface
of the electrode pins? If there is no fault present at the water
connection, the value for the water level can be checked in
the confi guration menu status during restarting, to check that
the level has changed from low to mid/high during fi lling. If
the level has not changed at all from low, both the mid and
high (M, H) pins are faulty. If the level has only changed to
mid, it is only the high pin (H) that is faulty
Poor wiring connection? Check by removing and refi tting the
RJ10 connector. Check that one of the pins in the female
RJ10 connector on the circuit board or control panel may
have become misaligned or displaced, so that contact with
the connected RJ10 cable has been lost.
The sensor at the NTC input has detected excessively high
temperature in the water tank. Check the steam pipe along
its length, and its dimensions. Check that the NTC is intact.
Resistance measurement should show approx. 10kΩ at 25˚C
and approx. 677Ω at 100˚C. Also check the water quality
and that automatic emptying is activated, so that the level
electrodes are not misleading the system due to foam in the
tank so that they believe that suffi cient water is available.
Try restarting the system. Check by removing and refi tting
the RJ10 connector. Check that one of the pins in the female
RJ10 connector on the circuit board may have become misa-
ligned or displaced, so that contact with the connected RJ10
cable has been lost. Check the screw terminal connections
on the sensor circuit board. Alternatively change the tempe-
rature/humidity sensor that is connected to the RS485 input.
Water level in the tank has been at least mid-level when
checking the tank is empty, carried out at all emptying
cycles. It must always be at its low level. Check, is the
water tank drain blocked? Is the emptying valve operating
and opening? Is the relay on the relay board that controls
the emptying valve closing? The fault may also be caused
by the high electrode pin sensing the value as water at the
same time as the mid not sensing water, the same as the
error code (level electrodes not working, mid failure) thereby
sending unknown water level.