Home (Fig. 13)
1.
Strain relief connector for cable to motorized ball valve
2.
Strain relief connector for AUX and lighting
3.
Lighting fuse (max. 0.5A)
4.
Strain relief connector for power supply cable
5.
Lead-through for the control panel, temperature sensor, etc. that will be connected by quick connectors to the circuit board.
Commercial (Fig. 13)
1.
Strain relief connector for cable to motorized ball valve
2.
Strain relief connector for power supply cable
3.
Lead-through for the control panel, temperature sensor, etc. that will be connected by quick connectors to the circuit board.
4.
Strain relief connector for AUX and lighting
5.
Lighting fuse (max. 0.5A)
6.
Fan fuse (max. 0.5A)
Lighting
Can be controlled from the control panel.
Refer to the connection label (Fig. 11) for the max. power specifi cation.
Positioning of thermistor
The sensor is to be installed 150-170 cm above fl oor level inside the steam room. Important! The sensor must be located as far from
the steam jet as possible. It must not be in either direct or indirect contact with the steam jet.
The thermistor wire can be extended beyond the steam room by means of a low voltage wire (2-core). Refer to the section "Modular
connector description" for information on the pin confi guration.
Option:
External switch - Can be positioned at any distance from the steam room. Connected by means of a low power cable and a RJ10
connector with pin connections as in the section "Modular connector description". Additional external switches must be connected in
parallel.
Door contact – Prevents unintended starting of the steam room while the door is open. Connected directly by means of a control board
and a RJ10 connector with low power wiring and pin connections as in the section "Modular connector description".
Connection to extra equipment
Possibility to connect extra equipment, such as fans, additional lighting, fragrance pump, etc. The number of functions it is possible to
connect is determined by the number of "AUX" inputs.
Product
Home
Commercial
Home automation
To start via a home automation system the input for external switches is used to trigger starting the steam generator. So as not to risk
inadvertent starting due to incorrect programming, it is recommended that a door contact is added to guarantee that the door is closed.
For other settings and programming, refer to the user's instructions for the control panel.
WARNING!
SEVERAL POWER SUPPLY CIRCUITS. BEFORE WORKING ON THE EQUIPMENT, CHECK THAT IT IS COM-
PLETELY WITHOUT VOLTAGE!
Multisteam
Steam Home and Steam Commercial 9/12/15kW off er the possibility of expanding and connecting together up to three facilities served
by the same control panel. This creates the possibility of unbroken steam production in all circumstances.
When more than one generator is connected together, one of them is set up to be the "Primary" (factory setting) and is the one which
controls the other generators. The other units are then set up to be "Secondary" in accordance with the DIP schematic diagram at Fig.
15.
Fig. 15
No. of AUX
1
3
121