18
•
T
he steam piping must not have any sharp bends.
•
D
o not direct the steam jet against walls, seats or other
A
objects.
lways keep a space of at least 80 cm clear in front
of the steam nozzle.
•
T
here must not be any water pockets in the steam piping
IMPORTANT! T
or ventilation ducts.
be any kind of blockage in the steam piping (e.g. taps or
T
valves).
he internal diameter of the steam piping must not
be reduced.
•
A
ll steam rooms in continuous use for more than two hours
must have an air exchange rate of 10-20 m³ air per person
per hour.
•
T
he power supply for the steam generator must not be cut
T
off .
herefore avoid installing a power switch, etc. in the
power supply line.
•
T
he drain pipe must have a continuous fall all the way from
the steam generator to the drain.
•
T
he ambient temperature for the steam room and steam
generator must not exceed 35°C.
•
T
he sensor must be located as far from the steam jet as
possible.
Plumbing installation – to be performed by a qualifi ed plumbing installer. Electrical installation – to be performed by a qualifi ed electrical
installer.
Installation diagram of Steam Home and Commercial (Fig. 1)
A= Power supply line from electrical distribution board to steam
generator. It is an advantage to install a circuit breaker
between the distribution board and the steam generator. The
circuit breaker must always be switched on. If the current
is switched off before automatic emptying and fl ushing of
the tank has taken place (about 70 minutes after bathing is
completed), the operation stops, the tank will not be emptied
and the life of the steam generator will be reduced.
B= Wiring from control panel to steam generator.
C= Thermistor wire
Fig. 1
IMPORTANT!
•
•
here must not
•
•
•
•
•
General
D= Wiring to optional external on/off switch
E= E= Steam pipe
F= Drain pipe.
G= Incoming water.
H= The outlet vent must be connected to a ventilation duct to
take the air outdoors.
I=
Supply air.
J= Pipe from safety valve.
K= Double swing check valve
1-6, see Fig. 12
D
escale the steam generator regularly in accordance with
the instructions, refer to the heading "Descaling".
with hard water, exceeding 4°dH hardness, a water softener
or Tylö MACH 2020 water softener must be installed (Tylö
Item no. 9090 8025)
C
lean the steam room regularly
NB! T
he steam generator drain must always lead to a drai-
nage channel outside the steam room.
empties its tank 1 hour after each bath, the water will then be
80-85°C!.
WARNING! T
here is a jet of hot steam from the steam
N
nozzle.
ever leave small children unattended.
T
his appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concer-
ning use of the appliance in a safe way and understand the
hazards involved.