Table des matières
Généralités ......................................................................................................... 4
Avant-propos .......................................................................................................................... 4
Avertissements et précautions .............................................................................................. 4
Conseils de sécurité ................................................................................................................ 4
FWD
Réception ................................................................................................................................. 4
Capacities
Cooling capacity on water (1)
Heating capacity on water (2)
Garantie ................................................................................................................................... 4
Fan motor
Fluide frigorigène ................................................................................................................... 4
Current amps (3)
Start-up amps
Contrat d'entretien .................................................................................................................. 5
Air flow
Stockage .................................................................................................................................. 5
Formation ................................................................................................................................ 5
Main coil
Water entering/leaving connections
Description du numéro de modèle de l'unité .................................................. 6
Electric heater (accessory for blower only)
Electric power supply
Heating capacity
Hot water coil (accessory for blower only)
Heating capacity (4)
G4 filter (filter box accessory)
Condensate pump (accessory)
Installation ....................................................................................................... 18
Water flow - lift height
Not available for FWD30 and FWD45
Réception des unités ........................................................................................................... 18
Sound pressure level (5)
Sound power level (5)
Installation de l'unité ............................................................................................................ 19
Unit dimensions
Vue d'ensemble de l'unité .................................................................................................... 20
Height
Shipped unit dimensions
Dimensions/Poids/Dégagements ......................................................................................... 21
Width x Depth
Raccordement du réseau de gaines .................................................................................... 21
Recommended fuse size
Installation des filtres ........................................................................................................... 22
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
*absolute service pressure: min 1 bar/max 11 bars
Raccordements électriques .................................................................................................. 25
Mode Refroidissement ......................................................................................................... 26
Mode Chauffage ................................................................................................................... 26
Mode Refroidissement ERC ................................................................................................. 27
Mode Chauffage ERC ........................................................................................................... 27
4
2
© 2017 Trane
Technical Data
08
(V/Ph/Hz)
(kW)
5,2
(kW)
6,3
(type)
0,23
(A)
1,1
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
20
230/1/50
8,3
15
11,9
18,9
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
486x271x8
586x321x8
2
2
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
300
350
1333 x 864
310
360
46
61
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
RT-SVX056C-FR