Connection Configuration Type 8626 / 8006 - Burkert 8626 Instructions De Service

Masquer les pouces Voir aussi pour 8626:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection configuration Type 8626 / 8006

8-pole socket (circular)
1
24V - supply +
2
Relay 1 - C contact
Relay 2 - C contact
3
4
Relay 1 - NC contact
5
Relay 1 - NO contact
6
24V - supply GND
7
Relay 2 - NO contact
Relay 2 - NC contact
8
NOTE
If a device of Type 8626 / 8006 (built before 2003) is to be replaced
by a new one (from 2003 on), this can be done by using an adapter
(see Appendix A) without additional cabling.
9-pole Sub-D socket (bus version only)
PROFIBUS DP
1
Shield (FE) functional earth
N. C. (not connected)
2
3
RxD/TxD-P B-line
4
RTS control signal for repeater
5
GND data transmission potential
VDD
6
supply voltage + (P5V)
7
N. C.
RxD/TxD-N A-line
8
N. C.
9
+15 pole Sub-HD socket
Analog drive
1
Setpoint input +
2
Setpoint input GND
Process value output +
3
4
5
12 V output (for factory unse only)
6
RS232 TxD (direct connection to PC)
7
8
DGND (for binary inputs)
For factory use only (do not connect!)
9
10
12 V output (for factory use only)
11
12 V output (for factory use only)
12
13
Process value output GND
14
RS232 RxD (direct connection to PC)
15
DGND (for RS232 interface)
DeviceNet
CAN_L data line
GND
N. C.
N. C.
N. C.
CAN_H data line
N. C.
N. C.
Bus version
N. C.
N. C.
N. C.
Binary input 2
Binary input 1
Binary input 3
N. C.
MFC/MFM - 31