Food serving trolley
Help in the event of faults
Service work should only be carried out by authorised specialist staff.
Defective components should only be replaced with original parts.
Please check first of all whether there has been an operating error. You yourself can eliminate some faults.
In the event of after-sales service and when ordering replacement parts give the data set out in the identifi-
cation plate (see page 16).
Fault
Appliance does not become
warm,
indicator light does not come
on.
Appliance becomes warm,
indicator light does not come
on.
Appliance only heats up very
slowly.
Regular inspection and maintenance of the appliance prevent disruptions to operation and ensure safety.
Inspection and maintenance intervals depend upon the use of the appliance. Consult your dealer's after-sales
service department.
Technical Data
Test mark
Appliance manufactured in accordance with
Water spray protection
Number of bowls
Bowl size
Average capacity in persons*
Heating
Connected load
Electrical connection
Heat insulation
Temperature regulation
Temperature range
Chassis
Nett weight without base edge
Appliance weight with maximum loading
of bowls, without base edges
Maximum localised load on base edges
Maximum area load on base edges
Permitted total weight
* The capacity is dependent upon the food recipe and the multiplicity of ingredients.
43.3000.2
Possible cause
Defective fuse at the building end. Check fuse and repair if need be.
ON/OFF switch defective.
Mains connection cable or
mains plug defective.
Indicator light defective.
Circuit defective.
Too much water in the bowl.
Limescale or dirt in the bowl.
SPA/EB-1
1
for GN 1/1 und sub-divisions thereof up to max. 200 mm depth
15
0,7 kW
4 castors, of which 2 with total locks, Ø 125 mm
32 kg
64 kg
50 kg
100 kg
170 kg
Action
Disconnect appliance from the mains
and have it checked and repaired if
need be by authorised specialist staff.
Take appliance out of operation and
have it checked and repaired if need
be by authorised specialist staff.
Reduce quantity of water
Take the appliance out of operation
and after cooling descale or clean the
bowl.
SPA/EB-2
SPA/EB-3
DIN 18867 – 7
IPX5
2
3
25
50
CNS tubular heating element
1,4 kW
2,1 kW
230 V 1N AC 50 Hz
ceramic mat
continuous, each bowl separate
30 – 95 °C
44 kg
55 kg
108 kg
151 kg
40 kg
30 kg
80 kg
65 kg
195 kg
220 kg
SPA/EB-4
4
80
2,8 kW
66 kg
194 kg
20 kg
50 kg
250 kg
25