NFU 50
6
Setup / adjustment
6.1 Mains connection
Prior to starting up the machine, check to ensure that the mains voltage corresponds to the operating voltage
specified on the rating plate of the machine.
The machine may only be connected to a socket outlet that is designed for an NEMA L6-30P plug. A standard
socket outlet does not supply the mains voltage required to operate the machine.
6.2 Routing of the connecting cable
Use the following procedure to route the
connecting cable:
1.
Route the connecting cable away from the
machine after it passes through the cable
grommet.
For support, use the Velcro fastener on
the hose connector.
2.
Always keep the connecting cable as far away
as possible from the tool.
Connecting cable routed.
If you are using a suction hose, also secure the cable to the suction hose using the
Kabelfix cable tie K-FIX (Order No. 205323).
12/2024
Warning
Electric shock when milling into the connecting cable
The connecting cable can impair safety functions and work functions and
get into contact with the tool. Milling into the connecting cable of your own
or another machine energizes the metal parts of the machine and causes
an electric shock. There is a risk of injury for the user.
When working, pay attention to the way the connecting cable is
routed.
Never mill into the connecting cable of your own or another machine.
Fig. 5: Routing the connecting cable