leave a protective coating to prevent
freezing or corrosion.
11. Wipe down the chiller, hose and gun with a cloth soaked in water or mineral spirits.
Problem
The power switch is on and the
generator is plugged in, but the
motor and pump are not running
24
13. TROUBLESHOOTING
Cause
The pressure is set to zero
The motor or controller is defective
A power outlet does not provide power
The extension cord is damaged
The electrical cable of the generator is
damaged
unit with more petroleum jelly oil. Place a
bucket with about 2 liters of petroleum
jelly oil under the suction pipe. Now we
put 2 pipes inside. We turn on the
cleaning mode and when we see that the
oil starts to flow out through the drain
pipe, we turn off the chiller, leaving the
oil inside. This will help prevent wet parts
from jamming, corroding, or rusting.
Before the next use, rinse the chiller with
water in the same way and when you see
that you have extracted all the oil from
the device, you can leave it for the next
use.
Solution
Turn the pressure control knob clockwise to
increase the pressure setting
Contact a service technician.
• Try a different outlet or plug in another
appliance that you know works to test the
outlet
• Reset the circuit breaker or replace the fuse
Replace the extension cord
Check that the wires or insulation are not
damaged. Replace the electrical cord if it is
damaged or contact an advisor.
WABRO Sp. z o. o.
ul. Arki Bożka 2A, Bytom
NIP: 6263044765 | Regon: 52012826

Publicité