S1: keypad tone ON, alarm tone ON (default)
S2: keypad tone OFF, alarm tone OFF
S3: keypad tone OFF, alarm tone ON
3. Touch and hold the UP key for 5 seconds to confirm
the selection.
TEMPERATURE DISPLAY
During normal operation, the temperature display on
the control panel shows the temperature inside the
appliance. The temperature display will flash if
-
A different temperature is being set,
-
The temperature in the zone deviates by more than
5°C (9°F) from the set temperature.
The temperature display flashing ensures that the
temperature cannot rise or fall unnoticed and impair
the wine.
TEMPERATURE MEMORY FUNCTION
In the event of a power interruption
breaker switch,
etc.), the unit remembers the previous
temperature settings. When the power is recovered,
the cabinet temperature will go back the same setting
temperature as before the power interruption.
TEMPERATURE ALARM
An audible alarm will sound if the temperature in one of
the zones rises or falls outside the temperature range.
The relevant temperature display will flash at the same
time (And the symbols
display for LCD Display units).
The temperature the appliance is set at determines the
temperature the appliance recognizes as being too
warm or too cool.
The audible alarm will sound and the temperature
display will flash:
-
When you switch the appliance on, if the
temperature inside the appliance is very different
from the temperature set.
-
When there has been a lengthy interruption to the
power supply.
-
When too many items have been
at one time.
Or too much ambient air flowed in
when rearranging and removing storage items.
-
When
the door is not been closed tightly.
-
The appliance is faulty.
The audible alarm will be automatically silenced, the
temperature display stops flashing (And the symbols
&
will go out for LCD Display units) when the set
temperature is reached again. However, if the noise
disturbs you, you can switch the audible alarm off
before this if you wish by touching any key once. The
alarm will stop. The relevant temperature display
continues to flash (And the symbols
continue to be lit up for LCD display units) until the set
temperature has been reached. The display then lights
Code Rev. E 20240815 (IEC)
(power surge,
&
will light up in the
put into the unit
&
will
up constantly, the symbols
display units, and the alarm system is fully active again.
HUMIDITY ALARM
A humidity audible alarm (if your model supplied with it)
will sound if the humidity inside the unit rises or falls
outside the humidity range. The relevant humidity
display will flash at the same time and the symbol
will light up. The flash of
humidity level and the flash of
too high humidity level.
The audible alarm will be automatically silenced, the
humidity display stops flashing and the symbols
will go out when the set humidity range is reached
again. However, if the noise disturbs you, you can
switch the audible alarm off before this if you wish by
touching any key once. The alarm will stop. The
relevant humidity display continues to flash and the
symbols
&
will continue to be lit up until the set
humidity has been reached. The display then lights up
constantly, the symbols
alarm system is fully active again.
DOOR ALARM
If the door has been left open for more than 60
seconds, the audible alarm will sound (And the symbol
will light up for LCD display units). Closing the door
or touching any key once can switch off the audible
alarm.
AUTO DOOR OPEN SYSTEM
(PushOpen DOOR FUNCTION)
The PushOpen door function (if your model supplied
with it) is activated when the unit is powered. To open
the door, push the door slightly inwards on the top left
position for the right hinge model (the top right position
for the left hinge model) and then release it. The door
will be opened a little away by the push piston. Then
the door can be fully opened manually. The push
piston will return to its initial position after 2 seconds
automatically.
NOTE:
-
To protect against inadvertent opening, the door
will close again by itself after approx. 2 seconds if
you do not pull the door open manually for
models with articulated hinges.
-
Do not block the door or hold on it while it is
opening. If the door is blocked or held during
opening, the auto door open system and the door
will be damaged. The loud and repeated cracking
noises will be heard.
-
Do not push the push piston in or hold on to it
during closing. If the push piston is blocked
during closing, it will no longer be able to reach
its initial position. In the initial position, the push
piston is flush with the front of cabinet. In order to
set the push piston back in its initial position,
disconnect the appliance from the mains, wait for
approx. 10 seconds and plug it back in again.
The push piston will return to its initial position.
20
&
will go out for LCD
LL and
indicates too low
HH and
indicates
&
will go out, and the
&