WARNING: If the ventilation gaps given are not
observed, the compressor will run more frequently and
for longer periods. This will result in increased energy
consumption and a higher operating temperature for
the compressor. This may, in turn, cause damage to
the compressor. It is essential to observe the
ventilation gaps given.
BUILT-IN CABINETRY INSTRUCTIONS
Make sure your installation does not block the front
ventilation grille. And be sure the door will open and
close properly in the chosen location.
a (mm)
100
1476
125
1768
170
1768
125S
1820
170S
1820
220
1820
NOTE:
To ensure proper service access and ventilation, A
must be at least 5mm more than a, B must be at least
5mm more than b and C must be at least 5mm more
than c.
For flush inset built-in installation, an extra 3mm door
clearance is required for dimension C.
ELECTRICAL CONNECTION
WARNING:
Improper use of the grounded plug can
result in the risk of electrical shock. If the power cord is
damaged, have it replaced by a qualified electrician or
an authorized service center.
All electrical work should be carried out by a suitably
qualified and competent person in accordance with
local and national safety regulations.
Check that the voltage marked on the product
corresponds with your supply voltage.
Code Rev. E 20240815 (IEC)
b (mm)
c (mm)
575
595
575
595
680
595
575
595
680
595
680
680
Connect this appliance to a separate at least 13A
circuit.
Connection should be made via a suitable switched
socket which is easily accessible. For extra safety it is
advisable to install a residual current device (RCD)
with a trip current of 30mA.
Have the receptacle and the circuit checked by a
qualified electrician to ensure that the socket is
grounded correctly.
Note: In locations where there is frequent lightning, it is
advisable to use surge protectors.
Do not connect the appliance to the mains electricity
supply by an extension lead. Extension leads do not
guarantee the required safety of the appliance (e.g.
danger of overheating).
The appliance must not be connected to an inverter
and must not be used with a plug adapter as these can
cause damage to the appliance's electronic unit.
The cord must rest securely behind the appliance and
not be allowed to lie or hang unprotected.
WARNING:
THIS APPLIANCE MUST BE EARTHED.
INSTALLING THE HANDLE
IMPORTANT: Do not overtighten the screws & do not
use power tools to install the handle.
DESIGN 1 –
1
Locate the handle (1) over the mounting stubs (3) of
the door and tighten the grub screws (2) with an Allen
key to secure the handle.
9
2
3