The used oil must be poured unto a suitable container and consigned to an authorized recycling center.
Do not release used oil into the environment under any circumstances.
8
PORTS AND CONNECTIONS
The VKH series pumps (see Fig. 4) are equipped with:
No. 2 "IN" inlet ports, 3/4" Gas.
Line connection to any of the two ports is indifferent for
proper pump functioning. The unused ports must be
hermetically closed.
No. 2 "OUT" outlet ports, Ø 8 mm.
No. 2 service outlets, 1/2" Gas; they can be used for the
gauge and the safety valve.
No. 1 "DRAIN" port supplied with adjustable 90° quick
coupling for polyamide tubes, outer Ø 10 mm; it is used to
recover the drainage of the seals pack cooling circuit and
must be connected to the drain, making sure that there is
no counter pressure.
Ambient temp. (°C)
8.1
Conic sealing pads
VKH pumps are equipped with 4 conical steel pads to be used
in correspondence with the pump outlet ports (see Fig. 5) or
in the optional fitting flanges. The function of the pads is to
guarantee pressure-tightness of the connection. The seat of
the pump's delivery port is already machined in order to hold
the conic pad; if necessary, the connections for the delivery
fitting or the closing plug must be specially machined as
indicated in Fig. 5/a.
At each disassembly, the conic pads must be
replaced.
PAD
Fig. 4
24
PLUG
PUMP HEAD
Fig. 5