Manufacturer
Lubricant
AGIP ACER220
Aral Degol BG 220
BP Energol HLP 220
CASTROL HYSPIN VG 220
CASTROL MAGNA 220
Falcon CL220
ELF POLYTELIS 220
REDUCTELF SP 220
NUTO 220
TERESSO 220
FINA CIRKAN 220
RENOLIN 212
RENOLIN DTA 220
Mobil DTE Oil BB
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Check the oil level, refill if necessary from the oil dipstick
pos. , Fig. 3.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing the
plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
chapter 11. The necessary quantity is:
~ 4.8 liters for versions with a reduction unit in pos. and
(Fig. 6). This amount will be slightly lower for pos. and .
~ 4.4 liters for versions with no reduction unit.
Set up the plant so that the oil temperature never
exceeds 110°C (230°F) during pump operation
under any circumstances.
Use a temperature probe to be inserted into the
oil drain plug pos.(2) fig.3. See "ATEX EXPLOSION
PROTECTION" manual.
ATTENTION: Use only oil with a flash point higher
than 200°C.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0°C - 30°C, follow
the instructions in the following diagram, considering that oil
must have a minimum viscosity of 180 cSt.
23
Fig. 3