According to ISO 16 602:2007 table E.1 or EN 14325:2018 table D.2, class 4 is the highest class that can be achieved with
the values determined.
Test chemicals
Ammonia,
CAS no. 7664-41-7
Chlorine,
CAS no. 7782-50-5
1)
Hydrogen chloride
,
CAS no. 7647-01-0
1)
n-Heptane
,
CAS no. 142-82-5
Sodium hydroxide 40 %,
CAS no. 1310-73-2
1)
Sulphuric acid 96 %
,
CAS no. 7664-93-9
1) The suit is not suitable for continuous exposure to this chemical
Test chemicals
Ammonia,
CAS no. 7664-41-7
Chlorine,
CAS no. 7782-50-5
2)
Hydrogen chloride
,
CAS no. 7647-01-0
2)
n-Heptane
,
CAS no. 142-82-5
Sodium hydroxide 40 %,
CAS no. 1310-73-2
2)
Sulphuric acid 96 %
,
CAS no. 7664-93-9
1) Laminate/Tricotril glove (Barrier and Tricotril glove)
2) The suit is not suitable for continuous exposure to this chemical
Instructions for use
|
Dräger CPS 6900
Umex
Class
4
4
4
4
4
2
Butyl glove
FKM glove
Class
Class
4
4
3
4
4
4
1
4
4
4
2
4
Fastener sys-
Seams
tem
Class
Class
3
4
3
3
2
4
2
4
4
4
3
3
FKM/butyl
Foil glove
glove
combina-
1)
tion
Class
Class
4
4
4
4
4
4
4
4
4
4
4
4
Technical data
Visor
Visor connec-
tion
Class
Class
4
4
4
4
4
4
4
4
4
4
4
3
Safety boots
Safety boots
(PVC)
(Nitril)
Class
Class
4
4
4
4
4
4
4
4
4
4
4
4
|