the date of manufacture. The service life may be reduced
despite correct storage and servicing if the suit is used
frequently.
8.3
Disposal information
The chemical protective suit must be disposed of in
accordance with the applicable regulations.
The chemical protective suits can be disposed of thermally
or on waste dumps. The form of disposal depends on the
contamination.
9
Technical data
9.1
General
Sizes in cm:
Suit size
Height
S
150-165
M
160-175
L
170-185
XL
180-200
XXL
195-210
Weight:
Suit size L,
approx. 6.8 kg
with size 45 boots,
without accessories
Suit size L,
approx. 8.0 kg
with size 45 boots,
with accessories
Suit size L,
approx. 4.3 kg
with socks,
without accessories
Material:
Chemical protective
Umex
suit
Visor
Special polyvinyl chloride
Gloves
FKM or
FKM/butyl or
butyl or
Laminate: HPPE or
Tricotril: Nitrile/Para-Aramid
Safety boots
Nitrile-P
black, FPA-CR safety boots with
plastic sole, cut and fire resistant,
textile lining inside, sizes(see "Order
list", page 32)
PVC:
yellow, black grip soles, sizes(see
"Order list", page 32)
Colours:
Outside/inside
red/red
Temperatures:
In usage
-40 °C to +60 °C
Instructions for use
|
Dräger CPS 6900
Chest size
Waist size
80-118
72-106
80-118
72-106
80-118
72-106
104-124
95-110
104-124
95-110
1)
Lower temperatures down to -80 °C
are
possible for short-term exposure
and have
been tested by Dräger for the mate-
rial Umex,
but not as part of the type examina-
tion.
Observe operating temperatures of
the respiratory protective equip-
ment!
In storage
-5 °C to +25 °C
1) Tested by Dräger
9.2
Resistance to penetration of
infectious agents
Test
Result
Resistance to con-
hydrostatic pres-
taminating liquids
sure:
under hydrostatic
20 kPa
pressure (with the
Phi-X174 bacterio-
phage)
1) according to EN 14126:2003+AC:2005
9.3
Resistance of the suit material
Test
Result
Abrasion resis-
>2000 cycles
tance
Flex-cracking
>100000 cycles
resistance
Flex cracking
>4000 cycles
resistance at
2)
-30°C
Tear resistance
57 N
Burst strength
643 kPa
Puncture resis-
>50 N
tance
Resistance to
self-extinguishing
flame penetration
Seam strength
>500 N
Tensile strength
>1000 N
1) according to EN 943-1:2015
2) according to EN 14126:2003+AC:2005
3) according to EN 1073-1:2016+A1:2018 and EN 1073-2:2002: Class 2
9.4
Resistance to permeation by
chemicals according to EN 943-
1:2015
For European approval, the tests against the concentrated
chemicals listed below took place by means of complete
wetting/coverage of the test samples.
The classification for testing the resistance to permeation by
chemicals in accordance with EN 943-1:2015 is provided as
follows:
|
Technical data
1)
Class
6
1)
Class
6
6
6
3
5
3)
3
fulfilled
6