Télécharger Imprimer la page

Dräger CPS 6900 Mode D'emploi page 20

Publicité

|
Safety-related information
1
Safety-related information
– Before using this product, carefully read these instructions
for use and those of the associated products.
– Strictly follow the instructions for use. The user must fully
understand and strictly observe the instructions. Use the
product only for the purposes specified in the intended use
section of this document.
– Do not dispose of the instructions for use. Ensure that they
are stored and used appropriately by the user.
– Only trained and competent users are permitted to use
this product.
– Do not use a faulty or incomplete product. Do not modify
the product.
– Notify Dräger in the event of any component fault or
failure.
– Comply with all local and national rules and regulations
associated with this product.
– Only trained and competent personnel are permitted to
inspect, repair and service the product. Dräger
recommend a Dräger service contract for all maintenance
activities and that all repairs are carried out by Dräger.
– Use only genuine Dräger spare parts and accessories.
Otherwise, the proper functioning of the product may be
impaired.
2
Conventions in this document
2.1
Meaning of the warning notices
The following warning notices are used in this document to
alert the user to potential hazards. The meanings of the
warning notices are defined as follows:
Warning
Signal word
sign
DANGER
WARNING
CAUTION
NOTICE
2.2
Trademarks
Trademark
Trademark owner
Dräger
®
®
FPS
, HPS
,
®
Panorama Nova
,
®
®
PAS
, PSS
, X-
®
plore
20
Classification of the warning
notice
Indicates an imminently haz-
ardous situation. If not avoided,
it will result in death or serious
injury.
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in death or serious
injury.
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in physical injury. It
may also be used to alert
against unsafe practices.
Indicates a potentially hazard-
ous situation. If not avoided, it
could result in damage to the
product or environment.
Trademark
Trademark owner
Ecolab
®
®
Eltra
, ECOLAB
Dr. Weigert
®
neodisher
KCL GmbH
®
Tricotril
Ansell
®
Barrier
Cryo-LNG™
Tempshield Inc.
2.3
Abbreviations
Abbreviation
Explanation
FKM
Fluoroelastomer
PVC
Polyvinyl chloride
3
Description
Dräger CPS 6900 are gas-tight chemical protective suits in
line with EN 943-1:2015+A1:2019 (Type 1a). They are re-
usable.
A compressed air breathing apparatus is required for the
breathing air supply. The compressed air breathing
apparatus, full face mask, and safety helmet are worn under
the chemical protective suit.For further information see:
"Tested personal protective equipment", page 21.
The chemical protective suit is equipped with exchangeable
gloves. The following gloves are available:
– FKM glove, if necessary with Tricotril overglove
– Butyl glove, if necessary with Tricotril overglove
– FKM/butyl glove, if necessary with Tricotril overglove
The following foil glove combinations are available:
– Laminate/Tricotril glove combination
The overgloves do not have to be used. However, they
offer an increased cut resistance.
The chemical protective suit can be equipped either with
socks made from the same material as the suit or with boots.
The socks by themselves do not provide adequate protection
from mechanical stresses. The user must therefore also wear
suitable protective boots which are approved in accordance
with EN ISO 20345.
A cuff prevents the penetration of substances between the
socks and safety boots.
The visor is provided with a scratch proof screen on the
outside of the suit.
The chemical protective suit features a pocket for radio units
and a push-to-talk button flap. The pocket is labelled with the
type ID.
The following optional components can be fitted to the
chemical protective suit:
– Control valve PT 120 L or Air-Connect:
Ventilation unit for the connection of external air supply
sources to the inside of the suit, with or without cooling
system.
– D-connect:
Bracket for additional equipment (e.g., thermal imaging
camera, measuring devices, rescue loops), which can be
fastened on the left or on the right hip.
Instructions for use
|
Dräger CPS 6900

Publicité

loading