Télécharger Imprimer la page

Bull 86 F1 20EG 01 Guide D'utilisation page 184

Publicité

error:
Sample File modem_m1.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP modem_m1
#
# FUNCTIONS: Modem configuration file specifically for IBM 7857–017 modem with
#
Auto–Reliable feature.
#
This example uses the AT&F reset command to choose the factory defaults.
#
#
To allow dial commands for digital pagers, it is necessary to reduce
#
the number of characters in the dial command.
#
been set to 6 seconds (S8=6) for that reason.
#
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials – Property of IBM
#
# US Government Users Restricted Rights – Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
ICDelay 1
DefaultTO 10
CallDelay 120
#
#
%N
#
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout:
connect:
retry:
disconnect:
C-10
Guide d'utilisation ESCALA PL820R
expect "0\r" or "OK\r\n" timeout 2
send "ATV0S0=0\r"
expect "0\r" timeout 2
done
expect "8\r" or "7\r" or "6\r" or "4\r" or "3\r"
delay 2
done
This feature must be turned off for Catcher calls.
Call–Out phone number
send "AT&F*E0E0\r"
ignore "0\r" or "OK\r\n" timeout 2
send "AT#F0*Q2S8=6\r"
expect "0\r" or "OK\r\n" timeout 2
send "ATV0X0S0=0\r"
expect "0\r" or "OK\r\n" timeout 2
done
send "ATDT%N\r"
expect "1\r" busy "7\r" timeout 60
done
send "A/"
expect "1\r" busy "7\r" timeout 60
done
delay 2
send "+++"
delay 2
send "ATH0\r"
ignore "0\r" or "OK\r" timeout 2
send "ATE0Q1\r"
ignore "0\r" timeout 1
done
# CD respond time=100ms
# Confirm commands successful.
# Numeric response code
# Auto Answer OFF
# Confirm commands successful.
#
# Handle unexpected modem
# responses.
Each comma (delay) has
%R
Return phone number
# Reset to factory defaults.
# *E0=data compression disabled
# E0=echo disabled
# Ignore modem response.
# Trellis modulation disabled
# Retrain with adaptive rate
# Set ,=6second
# Confirm commands successful
# Numeric response code
# AT compatible messages
# Auto–Answer disabled
# Confirm commands successful.
# Tone dialing command.
# %N from Call Home setup.
# Expect a connection response.
# Repeat the previous command.
# Expect a connection response.
# Separate from previous data.
# Assure command mode.
# Allow mode switching delay.
# Set modem switch–hook down
#
(i.e., hang up).
# Ignore modem response.
# Initialize modem: Echo OFF,
#
Disable responses.

Publicité