Lightingprocedurefor"PrimeZone"infraredburnerinmaingrillarea
1. Before starting the lighting procedure, all control knobs must be set to the
position "•" OFF.
2. Open the lid of the grill before you light the infrared burner.
3. Open the gas cylinder valve by turning anticlockwise (at least two full
turns).
4. Check all gas connections for leaks. See section "Leak check"
5. Press the control knob for the infrared burner inwards and turn it slowly
anticlockwise to the "MAX" position or until you hear the "click" of the Jet
Flame ignition system.
6. Hold down the control knob after the "click" for approx. 2 seconds so that the flame of the Jet Flame
can light the infrared burner.
7.
It is possible to visually check the ignition system. Look at the Jet Flame ignition area at the side from a
distance. After the ignition spark was triggered by the control knob, the gas flowing past is ignited and
a pilot flame is produced which lights the infrared burner.
8. If the infrared burner does not light immediately, turn the control knob back to "•" OFF and wait 2
minutes to allow the accumulated gas to disperse. Now you can repeat the ignition procedure.
9. You can now use the control knob to adjust the flame to suit your particular requirements.
For the lowest setting, you turn the control knob anticlockwise to "MIN".
10. If you do not succeed in lighting the infrared burner, refer to the section "Troubleshooting".
11. After use press in the control knob (gas valve) for the infrared burner and turn it clockwise to the posi-
tion "•" OFF.
59