Installation and connections
3.4.a - Chimney connection
Natural aspiration (Fig 11)
• Mount the plate (1) on the oven and fix it by means
of the specially provided screws (2).
Connect the plate (1) to a natural draught conduit
whose diameter is 85 mm.
Aspiration through an aspirator (Fig 12)
• Connect the aspirator delivery (4) to the flue through
a pipe, 120 mm diameter.

3.5 - FIRST STARTING

Once the oven is installed and before starting it,
carefully clean its inner part as well as refractory
surface as explained in "Maintenance" chapter, also
make sure neither foreign nor inflammable bodies
are inside the oven.
• Start the oven as prescribed in "Functioning" para-
graph, making sure the set temperature is correctly
reached and the different options (according to the
concerned model) properly function.
DANGER
ø 120 mm
4
FIG. 11
3
2
1
FIG. 12
EN - 17