Unipotential Connection; Oven Positioning - OEM PULSAR Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.3.f - Unipotential connection (Fig 9)
The equipment shall be inserted in a unipotential system,
whose effectiveness shall be verified according to the
rules being in force.
A cascade connection shall be carried out among the
various oven components by using the screw (1) placed
on the rear oven side.
3.4 - OVEN POSITIONING (Fig 10)
DANGER
The oven shall NOT be installed closed to inflamma-
ble walls such as furniture, partition walls, match-
boarded coatings etc...
A safety range of at least 50 mm from lateral and rear
oven sides should be kept.
No inflammable flooring shall be utilized to install the
oven on it.
In case the oven shall be built in, there shall be a
suitable change of air on its rear side and this can
be obtained by means of air grilles placed on the
wall.
• The oven shall be positioned on the final area follow-
ing the indications reported in figure 9, because they
indicate the minimum distances required to allow the
oven correctly to function.
• Fix the oven position by braking the rear wheels.
50 mm
EN - 16
IMPORTANT
50 mm
Installation and connections
FIG. 9
PULSAR
1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pulsar 435Pulsar 635-sPulsar 635-lPulsar 935

Table des Matières