Two-, three-chamber oven assembling (Fig 3)
(Only for G45/2-G45/3 models)
•
For the assembly of the double-chamber or of the
three-chambered oven, put the second oven (2) onto
the fi rst one (1) and fi x it by the clamps (3) and the
screws (4).
•
Concerning three-chamber ovens, the third oven shall
be put onto the second one and fi xed as above.
3.3 - ELECTRICAL CONNECTION (Fig. 6)
DANGER
•
The power feed line should be provided with a
suitable omnipolar DISCONNECTING SWITCH
(automatic thermomagnetic switch or differential)
placed before the control unit main switch, with
a minimum contact opening of 3 mm.
•
The earthing system should comply with the local
electric regulations in force.
•
The electric power cables should comply with
the maximum current required by the machine,
so that the total voltage drop at full charge will
be less than 2%.
•
The specifications of the electric power line
should correspond to the specifi cations of the
identifi cation plate and to those mentioned in
the technical specifi cations table that can be
consulted in the fi rst part of this booklet.
DANGER
Before connecting the machine with the electric
line, make sure that the DISCONNECTING SWITCH
is disconnected (line not energized).
3.3.a
- Electric oven connection
• Remove rear panel (1) to access the electric area of
the oven.
• Connect a suitably dimensioned electric cable (2) with
the terminal (3) according to the oven absorption,
the three phases shall be connected with F1-F2-F3
terminals, the neutral wire with N terminal, the earth
with T terminal.
• Insert the electric cable (2) in the special fairlead and
connect it with the disconnecting switch placed in the
upper part of the oven.
The disconnecting switch placed in the upper part of the
oven shall be easily to be reached.
• Remount rear panel (1).
EN - 12
IMPORTANT
FIG. 3
2
1
4
3
FIG. 4
1
2
F1
G45
Installation and connections
F2
F3 N
3
T