PULSAR
Installation and connections
3.3.b - Aspirator electric connection (Fig.6)
•
Unscrew the screw (2) to remove the casing (1).
•
Connect the cable to the terminal board (4).
•
Connect the phase to the terminal MV8, the neutral
wire to the terminal MV9, the earth to the terminal
T1.
The smoke extractor can be connected to any oven.
3.3.c - Electrical connections among ovens and
smoke extractor signal connection (Fig. 7)
•
Remove the casing (1) by unscrewing the screw (2)
of both the upper and lower oven.
•
For its connection, use the cable (5) as for the ex-
traction fan consisting of two wires, which when the
oven is being delivered, are available in an envelope,
inside the cooking chamber.
•
Connect the cable (5) to the terminals (6) and (7)
following the A and B terminal order. Refer to the
diagram in the picture.
•
Remount the previously removed casings.
3.3.d - Heated cell (optional) connection.
•
To connect the heated cell please see the manual
supplied with the latter.
3.3.e - Power limiter connection (Fig.8)
•
The oven can be connected to an external power
limiter, after the required connection, exclude two
terminals (1) and (2) on the terminal board, on the
back of the oven.
IMPORTANT
T1
MV9
MV8
4
7
B A
5
B A
6
6
1
2
FIG. 6
2
1
FIG. 7
2
1
FIG. 8
EN - 15