Electric Connection; Electric Oven Connection - OEM PULSAR Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3.3 - ELECTRIC CONNECTION

DANGER
The power feed line should be provided with a
suitable omni-polar DISCONNECTING SWITCH
(automatic thermo-magnetic switch or differential)
placed before the control unit main switch, with
a minimum contact opening of 3 mm.
The earthing system should comply with the local
electric regulations in force.
The electric power cables should comply with the
maximum current required by the machine.
The specifications of the electric power line
should correspond to the specifications of the
identification plate and to those mentioned in
the technical specifications table that can be
consulted in the first part of this booklet.
DANGER
Before connecting the machine to the electric line,
make sure that the DISCONNECTING SWITCH is
disconnected (line not energized).
L2
L1
L3
3
EN - 14
2
1
N
T
The disconnecting switch placed in the upper part
of the oven shall be easily to be reached.
In case of two- and three-chamber ovens, each oven
shall be connected with a special knife switch, it is
not possible to connect more than one oven to one
knife switch.
3.3.a - Electric oven connection (Fig.5)
Unscrew the screw (2) to remove the casing (1).
Connect the cable to the terminal board (3);
Connect the phases to the terminals L1, L2 and L3,
the neutral wire to the terminal N, the earth to the
terminal T.
Remount the casing (1).
PULSAR
Installation and connections
IMPORTANT
DANGER
FIG. 5