11
SPEED 1 is set to begin at 8:00am and run at 3000 RPM
for a duration of 2 hours. When SPEED 1 is complete
the pump immediately begins running the default
SPEED 2. SPEED 2 is factory default to 1400 RPM and
will last for 10 hours. When SPEED 2 has completed
its run the pump will run SPEED 3 at 2200 RPM for a
duration of two hours.
After 14 hours of run time and completing its run of
SPEED 3, the pump will enter a stationary/paused
state for the next 10 hours. The pump will restart at
8:00am the next morning and cycle through the default
schedule again. The pump will continue to run in this
in this manner until a custom schedule is programmed
into the drive by the user.
Note: The Start/Stop button must be pressed, and the
LED lit, for the pump to run.
Custom Schedules
To customize the run schedule for your VS2 Variable
Speed Pump, the pump must be stopped. Be sure that
the Start/Stop button LED is not illuminated.
Programming a Custom Schedule:
Note: When programming, the LED light next to the
parameter ("Speed", "Time" and "Duration") you are
setting will blink.
1. Stop the pump if it is running by pressing the Start/
Stop button.
2. Press the "1" button. The LED above the selected
SPEED will begin to blink and the "Speed"
parameter LED will blink while editing. See
Figure 8.
3000
Figure 8: Setting Speed
3. Use the "+" and "-" arrows to adjust the speed in
RPM for SPEED 1.
Note: Speed is adjusted up or down by increments
of 10 RPM.
4. Press the "1" button again and the display will
change to SPEED 1 start time. The "Time"
parameter LED will begin to blink. See Figure 9.
8 : 00
AM
Figure 9: Setting Start Time
5. Use the "+" and "-" arrows to adjust the daily start
time for SPEED 1.
6. Press the "1" button again and the display will
change to SPEED 1 duration. The "Duration"
parameter LED will begin to blink. See Figure 10.
2 : 00
Figure 10: Setting Duration
7. Use the "+" and "-" arrows to adjust the duration for
SPEED 1 in hours and minutes.
Note: The duration parameter is adjusted in 15
minute increments.
8. Pressing the "1" button will continue to cycle through
these parameters, but the changes are immediately
saved as they are adjusted.
9. Press the "2" button. The LED above SPEED 2 will
begin to flash and the corresponding parameter LED
will flash while editing.
10. Use the "+" and "-" arrows to adjust the speed in
RPM for SPEED 2.
11. Press the "2" button again and the display will
change to SPEED 2 duration.
Note: SPEEDs 2 and 3 do not have a start time, as they
begin their duration immediately after the previous
SPEED finishes.
12. Use the "+" and "-" arrows to adjust the duration for
SPEED 2 in hours and minutes.
13. Repeat steps 9-12 to program SPEED 3 and QUICK
CLEAN.
Note: Remember that the duration allowed for
SPEED 3 will be limited to the remaining time in
a 24 hour day. Any time in the 24 hour day not
programmed into SPEEDs 1-3, the pump will remain
in a stationary state.
[ SPEED 1 + SPEED 2 + SPEED 3 < 24 Hours ]