Corrections to FT -1 OOOMP EDSP lnsert for Ma nuai
,,-,The following FT-1000MP EDSP performance parameters have been preset at the factory.
Menu selection
Preset
2-9 (Notch Operation)
AUTO
4-4 (Transmit Audio EDSP)
4
4-5 (EDSP Receive Band Pass Filters)
SSB LPF
2400
SSB HPF
200
A1 BPF
240
A3 LPF
2400
A3 HPF
200
DIG FLT
PKT
7-7
(EDSP Enhanced Modulation & Demodulation) SSB RX
300-2800
SSB TX
200-3100
CW RX
ON
AM RX
ON
These setting are suggested starting points for the advanced aspects of the EDSP system.
Default
IF NOTCH
OFF
3200
100
240
3200
100
PKT
OFF
OFF
OFF
OFF
As you become more familiar with the Menu and EDSP system, you will undoubtedly want to make adjustments to
these or other settings.
To activate the Menu system to make parameter changes, press and hold in the [FAST] key, then press the keypad's
~ENT]
key
white holding in
the [FAST] key. Then rotate the [MEMNFO CH] knob to select the Menu item to be changed .
. ÏVhen you have made your changes to the Menu parameters, press [ENT]
again
to save your changes and exit to
normal operation.
Important Note !
These parameters have been preset through software, not firmware. Therefore, if you perform a master CPU
reset, the EDSP parameter settings will revert to the factory "default" settings shawn above, instead of the
"Preset" settings.
YAESU MUS EN CO,. L TD.