Télécharger Imprimer la page

Eurocave Vin au Verre 8.0 Mode D'emploi page 21

Masquer les pouces Voir aussi pour Vin au Verre 8.0:

Publicité

Les langues disponibles

Les langues disponibles

5. SALES STATISTICS
From the welcome screen, access the Settings Menu
Enter your "Manager" password and press
Then select
6. REPLACING THE NITROGEN CYLINDER
When the nitrogen cylinder is empty, the "Nitrogen empty" message appears on the screen.
Tip: remember to regularly check the nitrogen cylinder level on the pressure gauge.
The indicator light
will flash on the screen every 15 days.
When the level displays a pressure lower than 30 bars, remember to purchase a new cylinder.
1
Disconnecting the cylinder.
To do this, close the nitro-
gen cylinder then unscrew
using the pressure reducer
wrench (follow the connec-
Disconnect the
Déconnecter
cylinder
la bouteille
tion instructions explained
in Section III.3 in reverse
order)
EN
-18-
Choose the period you want to
select for analysing your sales:
"Today", "last 7 days" or "last 30
AUJOURD'HUI
TODAY
days".
Then validate
.
Your statistics will appear on the
screen. You can scroll through
Référence
Nombre
Volume en L
Chiffre
de verres
d'affaires €
all of the bottles by pressing
TOTAL
Tips: it is possible to delete all the statistics held by the
appliance by pressing DEL. The "manager password" will be
required to confirm this request. N.B., the data will be permanently
deleted.
Statistics can be consulted but cannot be exported.
2
Connect the new cylinder following explanations III.3.
3
Open the cylinder.
Check the pressure on
the outlet pressure gauge
(See. III.3).
Ouvrir la
Opening the
bouteille
cylinder
Regular monitoring of your appliance and reporting any faults to your stockist, will ensure that your appliance provides you with many years of faithful
service.
1. DAILY CLEANING
The Help indicator light flashes to remind you to carry out daily cleaning of your equipment. After 7 days of delay (this setting can be changed), your
equipment will no longer allow wine service in order to prevent oxidised wine in the circuit mixing with the wine served and altering its taste.
.
1
From the welcome screen, select
2
If you lose the cleaning bottle, use a recipient with a volume of 200 ml (a glass of water for example)
A recipient with a volume greater than 500 ml could cause the rinsing water to overflow from the drip tray.
When the drip tray is in the upper position, check the condition of the condensate collection drip trays located underneath the product. If you notice any
water, pull the 2 trays towards you and clean with a sponge.
2. MONTHLY CLEANING
It is important to carry out regular maintenance of your appliance. We
recommend monthly maintenance on the following elements:
Using a damp sponge, clean the different elements (1,2,3). The grids
can go in the dishwasher (4).
1/ Cleaning the drip tray, grids, and internal
compartments
16 °
C
6 ° C
15cl
3cl
6cl
16 °
C
6 ° C
6cl
15cl
3cl
C
16 °
2/ Cleaning the filters at the end of the plunge tubes
6 ° C
6cl
15cl
3cl
– Dismantle the plunge tube filters by pulling downwards (1)
1
– Rinse with warm water (2)
– Replace the plunge tube filters (3)
16 °
C
6 ° C
6cl
15cl
3/ Cleaning the seals
3cl
1
1
16 °
C
6 ° C
6cl
15cl
3cl
1
16 °
C
6 ° C
6cl
15cl
3cl
Dismantle the bottle connector socket guide by unscrewing it in an
anti-clockwise direction (1,2).
Clean the seal with a soft, damp cloth (3).
Reposition the bottle connector socket by repeating the process in the
reverse order (4,5).
EVERYDAY CARE
& MAINTENANCE
3
Place the drip tray in the
upper position following
the instructions on the
screen.
Validate
when you have done this. Cleaning is automatic.
4
When it is finished, empty the tray into a sink, return the tube to
its original location and return the drip tray to the low position.
4/ Complete cleaning of the circuit
Remove the wine bottles.
Go to the setting menu
,
1
Place a wine bottle filled with warm water (45°C) in one of the bottle
holders.
2
3
Press one of the three buttons to empty the bottle completely. Maintain
pressure on the button for a few seconds to dry the circuit.
1
Repeat the process on the 8 wine dispensing taps.
4
2
Then reposition the wine bottles and change back to
3
5/ Cleaning the outside of the appliance
Clean using a soft, damp cloth.
4
Tip: Lock measure dispensing on the touch screen
outside cleaning.
N.B.: Only use gentle cleaning products and do not pour liquid onto
2
the product.
eau
water
3
6/ Cleaning the 2 condensate collection drip trays
Remove the drip tray and check the condition of the condensate
collection drip trays located underneath the product. Clean with a
2
sponge or remove the trays to clean them.
eau
water
3
3
N.B. As part of normal operation and depending on weather conditions
(temperature/humidity), your equipment, by producing cold, may
produce natural condensation. This condensation residue is collected
1/4
2
by the trays located underneath your equipment. Remember to empty
these trays when carrying out monthly cleaning of your equipment.
3
5
7/ Cleaning the screen
Lock measure dispensing on the touch screen
1/4
1/4
2
4
Use a glass-cleaning product and a soft cloth. Spray the product onto
the cloth and clean the screen using the cloth.
5
Never spray the product directly onto the screen.
Dry the screen.
1/4
4
Important: the appliance may display a "cleaning detected" message
on the screen. Continue cleaning by drying the screen thoroughly.
Once the screen is clean and dry, the main screen will return after
30 seconds.
V
Remove the cleaning tube
from
the
hole
located
behind the drip tray when it
is in the lower position.
Cleaning
Insert this tube into the
Nettoyage
underway
en cours
cleaning bottle filled with
clean, warm water (45°C).
and change to manual mode
mode.
before
EN
-19-

Publicité

loading