INSTALLING
III
VIN AU VERRE 8.0
1. INSTALLING THE APPLIANCE
When your appliance is delivered, after unpacking, check the outside
and inside of your Vin au Verre 8.0 for signs of damage (dents,
buckling...). Open the doors and check that your appliance is intact
(walls, bottle connector sockets...).
If there is a problem, contact your EuroCave stockist.
Transport your appliance to its chosen location.
This place must:
•
be open to the outside to allow ventilation (not in an enclosed
cupboard)
•
not be close to a source of heat
•
not be too damp: for optimal use, max. 35°C/85% relative humidity
•
have a flat, stable surface
•
have a power supply (standard socket, 16 A, earthed with circuit
breaker, 30 mA* (* not applicable to some countries).
Precautions
•
Do not place your appliance in an area likely to flood.
•
Do not place the appliance close to a source of heat or in a place
where it is exposed to direct sunlight.
•
Prevent water or any other liquid from splashing onto any part of
the back of the appliance.
•
Position your appliance so that there is a minimum space of
5 - 10 cm between the wall and the back wall of your appliance.
•
Arrange the power lead so that it is accessible and does not come
into contact with any of the appliance's components.
•
Do not obstruct the ventilation inlets at the back of the appliance.
•
The ventilation inlets must be at least 5 cm away from any wall
or object.
•
Do not plug several appliances into a multi-socket adaptor and do
not use an extension lead.
•
Ensure that the water used for cleaning does not contain impurities
(in the form of large or small particles) in order to prevent wine or
gas leaks.
•
If it is necessary to cut the nitrogen supply lead, it is essential
that this is carried out with care in order to prevent the creation
of impurities (e.g.: a cutter). Other solutions could encourage gas
or wine leaks to arise.
2. FLUSH FITTING THE APPLIANCE
Observe the following instructions:
Dimensions in mm
1135
100
150
300
50
100
785
Allow sufficient room for the
power lead and nitrogen tube so
585
that they do not get damaged.
The unit must be strong enough
EN
to withstand 120 kg with the weight
of the bottles in use and spare bottles
-8-
Installation
Set the 4 feet independently in order to level your equipment 2 - 3°
towards the back, to allow condensate to drain.
Then, unwind the nitrogen cylinder connection tube located at the back
of the appliance and leave in place until you connect it up.
To perfectly align the appliance's doors horizontally
and correct any surface unevenness, you can tighten or
loosen the front feet with a 19 mm wrench.
Place the 2 condensate collection drip trays underneath the product.
Each tray is inserted into the 2 rails on either side of the product.
• Wait 48hrs before plugging in your Vin au Verre 8.0.
• When moving or installing the appliance, never tilt it
more than 45°.
i
1
100
Flush-fitting conditions:
• Ensure there is a space of 5 cm on either side and above
the product
50
• Ensure there is a space of 10 cm at the back of the product
50
• Provide a breather hole on top of the product
The breather hole must be
• on top of the appliance
• created at the edge of the back of the product
16 °
C
6 ° C
15cl
3cl
6cl
• 100 mm away from the side edge (on the right-hand side
735
of the product)
Recommended ambient temperatures
120 kg
1035
3. CONNECTING THE NITROGEN CYLINDER
N.B.: the nitrogen cylinder is connected via the back of the product - remember to connect it before flush fitting or before access to the back becomes
too complicated.
Type of nitrogen
cylinder
Aligal 1
Biolind 1
According to the place of installation, it is necessary to have the pressure reducer corresponding to your gas cylinder.
France, Spain, Singapore, Mexico, Israel, Belgium, UAE, Greece,
Morocco, Tunisia
USA, Canada
United Kingdom, Hong Kong, India, Taiwan, Thailand, Indonesia,
Argentina, Ireland, New Zealand, Vietnam, South Africa, Portugal
Germany, Netherlands, Denmark, Switzerland, Finland, Austria, Norway,
Sweden, Luxemburg
Australia
Japan
China
Italy
3
1
4
2
1135
30 mA
100
50
150
300
50
50
4. INSTALLING THE DRIP TRAY
1. Unscrew the 2 screws at the ends of the product, near to the notches, using a T25 Torque wrench
C
16 °
6 ° C
6cl
15cl
3cl
2. Insert the drip tray's 2 support brackets and screw back on.
735
3. Use a spirit level to check that the brackets are horizontal
785
4. Place the drip tray on the brackets, inserting the tabs into the slots and push against the product. The tray is magnetic and will be automatically
attracted to the product.
It is important to check that the brackets are horizontal to prevent the tray from rubbing against the doors.
1035
585
6 ° C
3cl
10°C
35°C
50°F
95°F
Permitted
Characteristics
pressure range
of the cylinder outlet
250 bars
Connection according to standard
The pressure reducer is set at
NFE29-650/C
the factory by the manufacturer
(female connection on the right, Ø
at the correct pressure: 0.6 - 0.7
21.7 mm, pitch 1.814 mm, SI thread)
bars (relative pressure)
Country
NFE29- 650/C
(female connection on the right, Ø 21.7 mm, pitch 1.814 mm, SI thread)
CGA 580 - M24 x 1.5 - MALE
BS341 - G5/8" - MALE
DIN 477 N°10 - W 24.32 -1/4'' RH - FEMALE
Type 50 - W24 x 2 - FEMALE
JIS B 8244 - W22x1/14'' - FEMALE
G5/8" - FEMALE
W21.7 x 1/14'' - MALE
2
5
90 kg
T25
T25
16 °
C
15cl
6cl
16 °
C
6 ° C
15cl
6cl
3cl
x 2
2
x 2
1
T25
4
Pressure reducer
Location of nitrogen cylinder
A 3 m tube is supplied > Install
the cylinder at a distance
allowed by the dimensions of
this tube.
It is not necessary to
change the pressure.
Type of pressure reducer connection
1. Remove the safety cap
6
2. Place the pressure reducer on the nitrogen
cylinder
3. Screw on using the pressure reducer
wrench.
4. Connect the supply pipe to the pressure
0.6 - 0.7 bars
reducer
5. Connect this same pipe to the appliance
6. Open the nitrogen cylinder. The pressure
must be 0.6 - 0.7 bars.
3
3
-9-