Fault description
-6-
-7-
-8-
-9-
Version Error
no speed indicator. Machine
version set in the time indi-
cator.
-b-
-c-
-d-
-E-
-F-
All indicator seg-
ments light up.
9.2
Performing a MAINS RESET
9.3
Emergency release
AB2300en
Cause
Overvoltage. Mains voltage
outside tolerances.
Overspeed. Error in the power
section.
Undervoltage. Mains voltage
outside tolerances.
Overtemperature. Overtemper-
ature switch in the motor has
tripped.
Wrong machine version set.
The control section skips to
the Settings menu.
Version Error. Wrong machine
version set. The control sec-
tion skips to the Settings
menu.
Underspeed.
Controller watchdog. Error in
the power section.
Lid lock error.
Short circuit in the control sec-
tion / power section.
Wrong machine version.
-
1.
Set the mains switch to
2.
Wait 10 seconds.
3.
Set the mains switch to
The lid cannot be unlocked by the motor in the event of a power failure.
Emergency unlocking by hand must be performed.
WARNING
Risk of electric shock due to maintenance and servicing
work on live device.
Disconnect the device from the mains before carrying
out repairs and maintenance.
Rev.: 12 / 10.2023
Remedy
Perform a MAINS RESET.
Check the mains voltage.
Perform a MAINS RESET.
Perform a MAINS RESET.
Check the mains voltage.
Open the lid using the emergency
release.
Let the motor cool down.
[t] buttons to set the letter C.
Use the
[STOP] button to save the
Press the
settings.
Perform a MAINS RESET.
[t] buttons to set the letter C.
Use the
[STOP] button to save the
Press the
settings.
Perform a MAINS RESET.
Perform a MAINS RESET.
Perform a MAINS RESET.
Perform a MAINS RESET.
Perform a MAINS RESET.
Notify customer service.
Notify customer service.
[0] .
[I] .