Instructions for installation and use
p. 12/62
Two-sensor mode with bench sensor (F2)
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna control unit displays
the temperature measured by the bench sensor as the actual temperature.
In two-sensor mode with bench sensor, the humidity is timed. Only the preset
value for the humidity (in % relative humidity) is shown on the display of the
sauna control unit. The actual humidity in the sauna cabin when the humidity is
timed depends on the size of the cabin and the vaporizer output, and may differ
from the setpoint.
Two-sensor mode with humidity/temperature sensor (FTS2)
When a humidity/temperature sensor is used in two-sensor mode, the sauna
control unit displays the temperature which is measured by the humidity/tem-
perature sensor as the actual temperature.
In two-sensor mode with humidity/temperature sensor, the vaporizer is regulated
in accordance with the humidity level measured in the sauna cabin. The sauna
control unit displays the actual humidity (in % relative humidity) in the sauna cabin.
If a humidity/temperature sensor is connected, the "vaporizer" menu item cannot
be hidden.